Response
Response Type
Response
Response
Type
Type
Type
Can be assigned to any wireless zone used
Fire with
as a fire zone. Fire with verification is
Verification
available with smoke detector device type. It
cannot
combination heat/smoke detectors or fire
pull stations. This zone type is always active
and cannot be bypassed.
Special-purpose zone type used with 5800
Arm–Stay
and SiX™ Series wireless keys.
Special-purpose zone type used with 5800
Arm–Away
and SiX™ Series wireless keys.
Special-purpose zone type used with 5800
Disarm
and SiX™ Series wireless keys.
No Response
Assigned when no-alarm response is required. •
Can be assigned to any wireless zone used
Monitor
for asset protection. Works as a dynamic
monitor of a zone fault/trouble (not alarm).
Assigned sensors or contacts on doors and
General Monitor
windows or asset protection within the
premises. Used to track activity of the
occupant and alert occupant of the activity
of others.
Assigned sensors or contacts on doors and
General
windows or asset protection within the
Response
premises. Used to track activity of the
occupant and alert occupant of the activity
of others.
Used to monitor a resident in an area
Resident Monitor
deemed to be dangerous by a caregiver.
Used to monitor a resident in an area
Resident
deemed to be dangerous by a caregiver.
Response
Requires acknowledgement by caregiver.
Garage
Assigned to Automatic Garage Door
applications. Provides a status of the garage
(Burglary)
door close/open real time state.
Assigned to Automatic Garage Door
Garage Monitor
applications. Provides a status of the garage
door close/open real time state.
Zone Resp
Zone Response Type Definitions
Zone Resp
Zone Resp
Function
Function
Function
Function
be
used
with
heat
detectors,
Lyric Gateway Installation and Reference Guide
onse Type Definitions (Continued)
onse Type Definitions
onse Type Definitions
• Alarm sound will pulse (Temporal Fire) when this zone type is
alarmed and the alarm has been verified.
• System verifies alarm by delaying reporting and alarm
sounding for 30 seconds after alarm is detected. If the zone
remains faulted after 30 seconds a fire alarm is provided. If
any other fire zone is faulted during the 30 second delay
window a fire alarm is immediately provided for that zone.
An alarm for original fire zone will also be provided, if that
zone is still faulted. If there are no fire alarms after the 30
second delay expires, the system will open a 60 second
window. If any fire zone is faulted during that window a fire
alarm will immediately be provided for that zone.
• Exit delay regardless of the arming mode selected.
• System armed in Home (Stay) mode when zone is activated.
• System is armed in the Away mode when the zone is
activated.
• Disarms the system when the zone is activated.
No reports to the Central Station.
No keypad sounding or chime and no display on screen.
• System can still be armed.
Reports to the Central Station, if enabled.
Fault/restore events are logged by the system.
Restore will be stored in event log.
No keypad sounding or chime.
System can still be armed.
• No reports to the Central Station.
• Fault/restore events are logged by the system.
• Monitors entry into a monitored area. Activates a one-time
announcement when faulted.
• No reports to the Central Station.
• Fault/restore events are logged by the system.
• Monitors entry into a monitored area. Activates a zone
announcement when faulted.
• System re-triggers audible sounding until acknowledged. (Off
sequence or wireless key)
• No reports to the Central Station.
• Monitors entry into a monitored area. Activates a zone
announcement when faulted.
• Fault/Restore events are not logged by the system.
• No reports to the Central Station.
• Monitors entry into a monitored area. Activates a zone
announcement when faulted.
• System re-triggers audible sounding every ten seconds until
acknowledged (Off sequence or wireless key).
• Fault/Restore events are not logged by the system.
• Associated With Entry Delay #2 Programmed Time.
• Exit delays when armed in Away, Home (Stay) or Arm Night
(Stay) mode.
• No Entry Delay when armed Away or Home (Stay) Instant
modes.
• System can be armed with zone faulted. When zone is closed
it will be included within protection points. If the point is
subsequently violated, it will initiate an alarm.
• Can be assigned to any wireless zone used for automatic
"Garage Door" Open/Close status.
• Will not initiate an alarm condition on the Gateway.
• When zone is in the open state will display "FAULT."
• Does not report alarms to Central Station.
• Zone chimes, if enabled.
System can be armed if this zone type is in fault.