Rf Transmitter Loop Numbers - Honeywell LyricLCP300-L Installation And Reference Manual

Table of Contents

Advertisement

RF Transmitter Loop Numbers

RF
RF
RF
Transmitter Loop Numbers
Transmitter Loop Numbers
Transmitter Loop Numbers
(Refer to this information when programming 5800 Series transmitters)
The following illustration shows the compatible transmitters, their associated input types and loop designations.
SERIAL #1
LOOP 1
(HEAT/SMOKE)
LOOP
1
LOOP 2
(MAINTENANCE)
LOOP 3
(LOW TEMP)
5 8 0 0 C O
5 8 0 0 C O M B O
E N R O L L A S
E N R O L L A S
S U P E R V I S E D
S U P E R V I S E D
LOOP
1
O N
LOOP 4
O F
F
5 8 0 0 S S 1
5804E
E N R O L L A S
ENROLL AS
S U P E R V I S E D
BUTTON
LOOP 2
(REED)
LOOP 1
(TERMINALS)
ALTERNATE POSITION
FOR LOOP 2
5 8 1 6
5 8 1 6 M N
E N R O L L A S
E N R O L L A S
S U P E R V I S E D
S U P E R V I S E D
LOOP
1
LOOPS
1 - 3
5 8 2 0 L
5 8 2 1
E N R O L L A S
E N R O L L A S
S U P E R V I S E D
S U P E R V I S E D
SERIAL #1
LOOP 3
SERIAL #1
A W
A Y
LOOP 2
SERIAL #1
S T
A Y
LOOP 4
1
2
SERIAL #1
SERIAL #2
3
LOOP 1
4
LOOP 3
SERIAL #2
LOOP 2
5 8 7 8
5 8 7 7
ENROLL AS BUTTON
NOTES: : : : (1) The 5806W3 smoke detector must be used in SIA applications.
NOTES
NOTES
NOTES
(2) Button type devices send only fault and low battery signals; no restore or check-in signals.
Supervised RF devices send periodic check-in signals, faults, restore and low battery signals.
(3) The 5804E and 5834-4 encrypted (High-Security) devices must be activated while the system is
in Go/No-Go Test Mode. Refer to the transmitter's Installation Instructions for complete details.
The system will confirm the enrollment of the encrypted device by beeping two times.
(4) The 5800PIR-OD, 5800SS1, 5804E, 5814, 5821, 5877, and 5878 wireless transmitters have not been
evaluated by ETL.
SERIAL #2
LOOP 1
(CO)
LOOP 2
(END OF LIFE)
LOOP
1
5 8 0 0 M i c r a
E N R O L L A S
S U P E R V I S E D
LOOP 3
LOOP 1
LOOP 2
LOOP 1
5806/5806W3/5807
5808/5808LST/5808W3
E N R O L L A S S U P E R V I S E D
LOOP 1
(TERMINALS)
LOOP 1
5 8 1 8 M N L
E N R O L L A S
S U P E R V I S E D
SERIAL #2
LOOP 1
LOOP 1
SERIAL #2
LOOP 3
SERIAL #1
LOOP 4
SERIAL #2
LOOP 2
5 8 2 2 T
E N R O L L A S
ENROLL AS BUTTON
S U P E R V I S E D
LOOP 1
(LOW SENSITIVITY)
LOOP 2
(HIGH SENSITIVITY)
5 8 9 8
E N R O L L A S
S U P E R V I S E D
Lyric Gateway Installation and Reference Guide
Wireless Zones
Wireless Zones
Wireless Zones
Wireless Zones (Continued)
LOOP 1
5 8 0 0 P I R - R E S
E N R O L L A S
S U P E R V I S E D
LOOP 1
LOOP 1
5809
5 8 1 1
E N R O L L A S
E N R O L L A S
S U P E R V I S E D
S U P E R V I S E D
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(TERMINALS)
5 8 1 9
E N R O L L A S
S U P E R V I S E D
LOOP 1
SERIAL #2
LOOP 4
SERIAL #1
LOOP 1
5 8 5 3
5834-4
E N R O L L A S
S U P E R V I S E D
LOOP 3
LOOP 2
LOOP 4
LOOP 1
LOOP 5
SiXFOB
- 13 -
5 8 0 0 P I R / 5 8 0 0 P I R - C O M
5 8 0 0 P I R - O D
E N R O L L A S
E N R O L L A S
S U P E R V I S E D
S U P E R V I S E D
LOOP 1
(TERMINALS)
LOOP 2
(REED)
LOOP 1
5814
E N R O L L A S
S U P E R V I S E D
LOOP 1
(INTERNAL
LOOP 2
SHOCK
(REED)
SENSOR)
LOOP 3
(TERMINALS)
5 8 1 9 S
E N R O L L A S
S U P E R V I S E D
5869
5870API
E N R O L L A S
E N R O L L A S
S U P E R V I S E D
S U P E R V I S E D
LOOP 1
(LOW
SENSITIVITY
LOOP 2
(HIGH
SENSITIVITY)
LOOP 3 (TEMP)
LOOP 4 (TAMPER)
5 8 1 5 W G / 5 8 1 5 W G - B R
E N R O L L A S
S U P E R V I S E D
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
5 8 1 9 S ( W H S & B R S )
E N R O L L A S
S U P E R V I S E D
LOOP 1
(HIGH
SECURITY)
LOOP 2
(STANDARD
SECURITY)
LOOP 3 (TILT MODE)
LOOP 4 (TAMPER)