Event Log; Contact Id Event Log Codes - Honeywell LyricLCP300-L Installation And Reference Manual

Table of Contents

Advertisement

Lyric Gateway Installation and Reference Guide
System Operation (Continued)
System Operation
System Operation
System Operation

Event Log

Event Log
Event Log
Event Log
The Lyric Gateway Series event log is capable of recording and displaying up to 6,000 system events. These
events are stored locally in the Gateway, in chronological order, and transmitted to the Central Station. When
the maximum number of events is reached in the Event Log, the system will overwrite the oldest event first. The
type of events that can be recorded is selectable and is programmed in the System Type programming field.
The event log can be reviewed from the AN360 app's Installer Tools screen by selecting "Event Logs" or the
Installer Advanced screen by selecting "Event Log". Refer to the Lyric Gateway User Manual for additional
information. The Events and CID Codes displayed vary according to the options that are programmed. The
tables below provide definitions of the events/codes that may be transmitted to the Central Station and/or
displayed in the Gateway's Event Log.
NOTE: : : : In the unlikely condition that the backup battery becomes fully discharged when AC power is lost, any system activity
NOTE
NOTE
NOTE
performed after the low battery notification will not be saved in the event log. Additionally, the Gateway will revert to the
status condition as before the low battery notification.
CID Code
CID Code
CID Code
CID Code
110
Alarm, Fire
121
Alarm, Duress
122
Alarm, Silent
123
Alarm, Audible
131
Alarm, Perimeter
132
Alarm, Interior
134
Alarm, Entry/Exit
135
Alarm, Day/Night
137
Alarm, Tamper
145
Expansion Module Tamper
146
Silent Burglary
150
24-Hour Non-Burglary
162
Carbon Monoxide Detected
301
Trouble, AC Loss
302
Trouble, Low System Battery
305
Trouble, System Reset
308
System shutdown
316
System Tamper*
341
Trouble, Case Tamper
344
Trouble, RF Receiver Jam Detect
350
Long Range Radio Reset
353
Trouble, Long Range Radio Transmitter Fault
354
Failure to Communicate Event
373
Trouble, Fire Trouble
374
Trouble, Exit Error Alarm
380
Trouble, Sensor
381
Trouble, Loss of Supervision RF
383
Trouble, Sensor Tamper
384
RF Low Battery
401
Open/Close by User
403
Open/Close Automatic
406
Cancel
407
Remote Arm/Disarm
408
Quick Arm
441
Armed Stay
455
Auto-Arm Failed
459
Recent Close
461
Wrong Code Entry
570
Zone/Sensor Bypass
601
Manual Trigger Test Report
602
Periodic Test Report
606
Listen-in to follow
607
Walk Test
623
Event 90% Full
627
Program Mode Entry
628
Program Mode Exit
654
System Inactivity
655
Reset Master Code
* AlarmNet 360 generates a special comm. fail message (E316) if it does not hear from a unit within 15 minutes after a delayed alarm is
delivered. This message is meant to alert the Central Station that the system has been tampered with and may have been
compromised.
ID ® ® ® ® Event
Contact ID
Contact
Contact
Contact
ID
ID
Event Log
Event
Event
Definition
Definition
Definition
Definition
- 24 -
Log Codes
Log
Log
Codes
Codes
Codes
Event Log Display
Event Log Display
Event Log Display
Event Log Display
Fire
Duress
Silent
Audible
Perimeter
Interior
Entry/Exit
Day Night
Tamper
Expansion Module Tamper
Silent Burglary
24 Hour Non-Burglary
Carbon Monoxide Detected
AC Loss
Low system battery
System Reset
System shutdown
System Tamper
Cover Tamper
RF Jam Detect
Long Range Radio Reset
Comm. Trouble
Failure to Communicate Event
Fire trouble
Exit error alarm
Sensor trouble
Superv Loss-RF
Sensor Tamper
RF Low Battery
Arm Away/Disarmed
Automatic O/C (or Scheduled Arming)
Cancel
Remote Arm/Disarm
Quick arm
Arm Home/Disarmed
Auto-arm Failed
Recent Closing
Wrong Code Entry
Zone Bypass
Manual Trigger Test Report
Periodic test report
Listen-in to follow
Walk Test Mode
Event Log 90% Full
Program mode entry
Program mode exit
System Inactivity
User Code

Advertisement