8.
DVDR980-985 /0X1
8.2
Reprogramming Procedure of NVM on the
Analogue PCB
The NVM, item 7815, on the Analogue board contains the
following factory settings:
1. Bargraph 0dB correction factor
2. Clock correction factor
3. AFC reference value
4. Slash version
The settings 1,2 and 3 are stored in the NVM during the
production of the analogue board.
The slash version is stored at the end of the production line of
the set.
In case of failure, the NVM must be replaced by an empty
device. By way of commands via the Diagnostic Software or via
ComPair, the factory settings must be restored in the NVM.
8.2.1
Bargraph 0db Alignment
For an exact functionality of the bar graph in the display, a
correction factor for the left and the right channel is stored in the
NVM.
Procedure:
Put the set in DSW command mode
route Audio path from Audio front connectors to digital with
the following command:
DD:> 713 01
apply a sine wave of 1 kHz, 1.65 Vrms (0 dB) to the front
connectors, audio left and right
store 0 dB bar graph level with command 720
DD:>720
8.2.2
Clock Correction Adjustment
To guarantee an exact function of the real time clock, an
adjustment of the clock frequency is possibe and stored in the
NVM.
Procedure:
Connect a pull up resistor of 10k between pin 7 an 8 of the
clock IC PCF8593T, item 7811, on the analogue PCB
put the set in service command mode
execute command 722 to initiate that a 1 Hz signal is
available on pin 7 of the clock IC
DD:>722
measure the frequency of the Clock Crystal with an
accuracy of ±1(s. Normally the measured frequency must
be between 999902 (s and 1000097 (s. If the frequency is
outside this range, the clock IC must be replaced.
Execute command 721 with the measured frequency as an
input parameter
example:
DD:>721 1000023
8.2.3
AFC Reference Voltage Tuner
This function stores the reference voltage for the tuner in the
NVM. Before this value can be stored, the AFC adjustment,
described in the adjustment instructions of the analogue board,
must be carried out.
Procedure:
Adjust AFC circuit
Calculate the reference value
Execute command 732 and use the calculated reference
value as parameter
example:
DD:>732 128
Alignments
8.2.4
8.3
8.3.1
8.3.2
8.3.3
Slash Version
The slash version is stored with command 715 followed by the
slash version as parameter.
The slash versions used in DVDR1000 and DVDR1500 are the
following:
DVDR980/00X:
2
DVDR980/02X:
2
DVDR980/05X:
4
DVDR985/00X:
5
DVDR985/02X:
5
DVDR985/05X:
6
Example:
DD:>715 1
Reset of Slash Version
Use command 729 to reset the analogue board to the default
setting.
Procedure:
Put the set in DSW command mode
Execute command 729 with the following parameters:
DD:> 729 w 0xA0 3 0x07 0xD0 0x00
Leave the DSW command mode and start up the set in
application mode No background is visible on the TV
screen. The analogue board is ready to accept the
appropriate slash version.

Rework Procedure IEEE Unique Number

Scope:
The procedure describes how to upgrade sets with a unique
number after repair. This unique number is stored in the
NVRAM (item 7201) of the digital board at the end of the
production line.
This procedure is only valid or necessary when:
The digital board is replaced
NVRAM on the digital board is replaced
NVRAM is cleared
In all other cases the repaired set retains its unique number.
The procedure defines several means to re-assure the unique
number depending on the possibilities of repair or the state the
faulty set is in.
Handling:
State of Original (Defective) Board:
1. The digital board starts up in Diagnostics Mode: follow
procedure A to retrieve the valid unique number
2. The digital board does NOT start up in Diagnostics Mode:
follow procedure B.
Procedure A
1. Connect defective digital board to PC via serial cable (3122
785 90017)
2. start up hyper terminal or any other serial terminal via the
correct settings (DSW command mode interface)
3. read out existing unique number via nucleus 403
example:
DD:> 403
40300: DV Unique ID = 00D7A1FC6C
Test OK @
4. note read out
5. program new digital board via nucleus 410
example: DD:> 410 00D7A1FC6C
41000:
Test OK @
The set has now the original unique number