Correcting Failures; Flashing Codes Indicating The Status Of The Control Panel - Paravan PR 50 User Manual

Table of Contents

Advertisement

20.

Correcting failures

20.1

Flashing codes indicating the status of the control panel

Error Message:
Centre Joystick
Low Battery
Inhibit active
Correcting failures
Meaning:
The most common cause of this error is that the joystick is not centred when the
control system is switched on. "Joystick off-centre" will appear on the display for five
seconds. If the joystick is not released within this time, an error will be generated.
Please ensure that the joystick is centred and then switch the control system on. When
switching on the control system, make sure that you do not touch the joystick button
with your hand.
This message appears when the control system detects that the battery voltage has
dropped below 16 V. Check the state of the batteries and the connections in the con-
trol system. High battery voltage.
This message appears when the control system detects that the battery voltage has
risen above 35 V. The most common reason for this is that you have overcharged the
battery or there is a bad connection between the control system and the batteries.
Check the state of the batteries and the connections in the control system.
This message appears when one of the blocking inputs is active and locked.
Switch the control system off and on again. This will remove the system lock and may
get rid of the error. Check all cables and switches on the corresponding blocks.