Gree GVA24AL-K3NNC7A/I Service Manual page 94

Refrigerant:r410a
Table of Contents

Advertisement

Service Manual
Resistance Table of Discharge Temperature Sensor for Outdoor(50K)
o
Temp(
C) Resistance(kΩ)
-29
853.5
-28
799.8
-27
750
-26
703.8
-25
660.8
-24
620.8
-23
580.6
-22
548.9
-21
516.6
-20
486.5
-19
458.3
-18
432
-17
407.4
-16
384.5
-15
362.9
-14
342.8
-13
323.9
-12
306.2
-11
289.6
-10
274
-9
259.3
-8
245.6
-7
232.6
-6
220.5
-5
209
-4
198.3
-3
199.1
-2
178.5
-1
169.5
0
161
1
153
2
145.4
3
138.3
4
131.5
5
125.1
6
119.1
7
113.4
8
108
9
102.8
Installation and Maintenance
o
Temp(
C)
Resistance(kΩ)
10
98
11
93.42
12
89.07
13
84.95
14
81.05
15
77.35
16
73.83
17
70.5
18
67.34
19
64.33
20
61.48
21
58.77
22
56.19
23
53.74
24
51.41
25
49.19
26
47.08
27
45.07
28
43.16
29
41.34
30
39.61
31
37.96
32
36.38
33
34.88
34
33.45
35
32.09
36
30.79
37
29.54
38
28.36
39
27.23
40
26.15
41
25.11
42
24.13
43
23.19
44
22.29
45
21.43
46
20.6
47
19.81
48
19.06
o
Temp(
C) Resistance(kΩ)
49
18.34
50
17.65
51
16.99
52
16.36
53
15.75
54
15.17
55
14.62
56
14.09
57
13.58
58
13.09
59
12.62
60
12.17
61
11.74
62
11.32
63
10.93
64
10.54
65
10.18
66
9.83
67
9.49
68
9.17
69
8.85
70
8.56
71
8.27
72
7.99
73
7.73
74
7.47
75
7.22
76
7.00
77
6.76
78
6.54
79
6.33
80
6.13
81
5.93
82
5.75
83
5.57
84
5.39
85
5.22
86
5.06
87
4.90
o
Temp(
C)
Resistance(kΩ)
88
4.75
89
4.61
90
4.47
91
4.33
92
4.20
93
4.08
94
3.96
95
3.84
96
3.73
97
3.62
98
3.51
99
3.41
100
3.32
101
3.22
102
3.13
103
3.04
104
2.96
105
2.87
106
2.79
107
2.72
108
2.64
109
2.57
110
2.50
111
2.43
112
2.37
113
2.30
114
2.24
115
2.18
116
2.12
117
2.07
118
2.02
119
1.96
120
1.91
121
1.86
122
1.82
123
1.77
124
1.73
125
1.68
126
1.64
91

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents