Gree GVA24AL-K3NNC7A/I Service Manual page 89

Refrigerant:r410a
Table of Contents

Advertisement

Steps
9.Remove 4-way valve
Twist off the nuts used for fixing the 4-way
valve wire, and then take out the coil. Use wet
guaze to wrap the 4-way valve, unsolder the
spot weld connected to the 4-way valve and
then remove the 4-way valve. The welding
process must be as quick as possible, and
then gauze should be kept wet all the time.
Please note that don't let the flame burn the
leading wired of compressor.
10.Remove valve
Remove screws used for fixing the valve,
unsolder the pipeline connected with the valve
and then remove the valve.
11.Remove compressor sub-assy
Unsolder the pipeline connected with the
compressor, remove 3 foot nuts on the
compressor, and then the compressor and the
gas-liquid separator can be removed.
86
Procedure
Gas-liquid separator
Compressor
Service Manual
4-way valve
Valve
Installation and Maintenance

Hide quick links:

Advertisement