Software Update Procedure

When software is updated on the ADM the software is
then automatically updated on all connected GCA com-
ponents. A status screen is shown while software is
updating to indicate progress.
1. Turn system main power switch OFF.
2. Remove ADM from bracket.
3. Remove token access panel.
F
. 62: Remove Access Panel
IG
4. Insert and press InvisiPac software upgrade token
(T, part no. 24R324) firmly into slot.
NOTE: There is no preferred orientation of token.
T
F
. 63: Insert Token
IG
5. Install ADM into bracket.
6. Turn system main power switch ON.
A status is shown while software is updating to
indicate progress. To prevent corrupting the software
load, do not remove token until the status screen
disappears.
333347F
r_24P860_3B9900_3a
r_24P860_3B9900_4a
NOTICE
NOTE: When the screen turns on, you will see the fol-
lowing screens:
First:
Software is checking
which GCA modules
will take the available
updates.
Second:
Status of the update
with approximate time
until completion.
Third:
Updates are complete.
Icon indicates update
success/failure. See
the following Icon
table.
Icon
Description
Update successful.
Update unsuccessful.
Update complete, no changes
necessary.
Update was successful/com-
plete but one or more GCA
modules did not have a CAN
boot-loader so software was
not updated on that module.
7. Remove token (T).
8. Replace token access panel.
9. Press
to continue to the InvisiPac operation
screens.
Repair