Accessories
System Stand, 24R088
Use the stand to mount the system at eye level. When
the system is mounted on the stand, the ADM is 45 in.
(1.14 m) above the bottom of the stand.
Ref
Part
Description
1001
---
STAND
1002
112395 SCREW flange head cap
1003
112958 NUT, hex, flanged
System Stand Installation
1. Place stand (1001) in desired location.
2. Use bolt holes to bolt stand in place.
3. Place system on stand.
4. Use screws and nuts to secure system to stand.
Caster for Stand, 120302
Caster with friction post mounts directly to
system stand using no extra hardware. Four
required. Casters raise stand an additional
4.25 in. (108 mm).
102
Adapter Plate, 24R083
Use this adapter plate to install InvisiPac in place of an
existing hot melt applicator system.
Bolt Hole Dimensions
A
9.8 in. (249 mm)
B
14.843-15.157 in.
(377.0-385.0 mm)
C
17.003-17.317 in.
(431.9-439.9 mm)
1002
1001
1101
1003
1102
1103
Ref
Part
1101
---
1102
112395 SCREW flange head cap
1103
112958 NUT, hex, flanged
1104
121283 FITTING, elbow, 45 degree
Qty
Adapter Plate Installation
1
1. Remove existing hot melt applicator system.
3
3
2. Use six screws (1102) and six nuts (1103) to secure
adapter plate (1101) through the existing holes from
the previous system.
3. Align the InvisiPac system with the bolts on the
adapter plate (1101) then place onto the adapter
plate (1101).
4. Use the remaining three nuts (1103) to secure the
InvisiPac system to the adapter plate (1101).
5. Use elbow fitting (1104) to install system air inlet
filter (A, not included with kit).
A
Description
PLATE, adapter
C
B
1104
A
Qty
1
6
9
1
333347F