Problem
Cause
Static shock
Ground wire not in
when touching
place on shaker
shaker or
assembly. Some adhe-
adhesive bin.
sives, flow rates, and
ambient conditions can
cause excessive static
buildup on the shaker
tube.
Adhesive not
Dispense modules
dispensing at
opening at the wrong
the correct
time.
time.
Pump and vac-
Solenoid connector is
uum feed sys-
installed into the light
tem cycle on
tower plug on the
and off before
MZLP daughter board
temperature
setpoint is
achieved.
333347F
Solution
Attach a ground wire from the shaft of the shaker unit to a true earth
ground. Order shaker grounding kit 24R708.
InvisiPac system does not control the opening and closing of the appli-
cators. The separate controller needs to be adjusted. Consult pattern
control manufacturer or qualified electrician.
Move solenoid connector from J12 (light tower) to J13 (solenoid
valves) on the daughter board on the MZLP.
Troubleshooting