Table 15. System-load Phase Error Messages
Message
Meaning
Recovery Procedure
CP AREA TOO SMAll
The size of background has changed
If background checkpoint is required, the
and/or disk area allocated for the
entire SYSGEN must be redone with either
CP area is too sma" for all of back-
a larger CP area allocation or the default
ground memory.
allocation for CPo
(If ANALYSIS, CP was
specified during phase 1, SYSERR will not
be able to write to the CP area.)
CP AREA TOO SMALL TO
The ANALYSIS, CP option was selected
If complete analysis dump is required, re-
CONTAIN ENTIRE
and the CP area a IIocation was not
run entire SYSGEN with a larger (or de-
ANAL YSIS DUMP
sufficient to contain all of memory.
fault) CP area allocation.
INVALID PARAMETER
An invalid response has been mode
Retype either All, UPD, or PA.
to the INPUT OPTION request.
UPROTECT RAD
One of the write-protect switches
Reset the write protect switches for the ap-
has been set on the disk for an area
propriate area.
that phase 2 is attempti ng to modify.
EOT ON SP AREA
An end-of-tape status has been re-
A new SYSGEN will have to be performed
turned whi Ie writing on the SP area.
with an increase in the SP area.
Not enough room has been allocated
for the SP area.
E OT ON SD AREA
Some as for SP, except the SD area
Same as for SP.
has overflowed.
RDdn FAULT
A nonexistent address has been given
Check disk allocation parameters in phase 1
for a seek operation.
for allocation of more tracks than exist on
this disk.
Repeat Phose 1 and/or Phase 2.
MASTER DICT. O'FlOW
Version of RBM on disk has a larger
last areas of old dictionary were lost.
A
Master Dictionary than new version.
complete new SYSGEN may be necessary.
UPDATE UNSUCCESSFUL
The previous Moster Dictionary
The new SP area must be at the same disk
could not be located, or the location/
address as the previous SP area, otherwise,
si ze of one or more areas has changed.
the ALL option must be used.