Du ri ng the RE PLACE run, the operator wi" be requested to
set the PROTECT switch to OFF and then to ON to al-
low REPLACE to alter protected memory.
GENERATION OF SYSGEN INPUT TAPE
The procedures described here are directed to analysts and/
or customers who wish to generate a SYSGEN-input mag-
netic tape containing updated resident and/or nonresident
RBM modu les replacing modules on the system release tape.
REPLACE DIAGNOSTICS
The diagnostic messages output by RE PLACE and their mean-
ings are itemized in Table 16.
REPLACE OPERATOR MESSAGES
Step 1 - Expand all source modules that require updating.
The REPLACE processor may output the messages in Table 17
during execution.
Step 2 - Assemble each module in order.
Table 16. REPLACE Diagnostics
Message
Meaning t
OVERLAY NOT PRESENT IN OVLOAD
xx was not found as an overlay identifier.
NEW OVERLAY TOO LARGE
After extending xx to its maximum size, the new overlay exceeds the
available space or is larger than the overlay area (512 words).
OVERLAYS BIAS SHOULD BE +xxxx
The bias used when the load module read from OV was found is not the
bias used by the system (this check is not made for JCP). xxxx will give
the proper bias.
NO ID FOUND ON REPLACE CALL
The !REPLACE IDxx call is not in correct format; thus, the ID field cannot
be located.
ERROR CO DE xx
0
N HEADER READ
Error code xx has been received while attempting to read record 0 from OV.
ERROR CODE xx ON OVERLAY READ
Error code xx has been received while attempting to read the rest of the
load module, beginning at record 1 from OV.
ERROR CODE xx ON OVERLAY WRITE
Error code xx has been received while attempting to write the overlay to
the SP area.
ERROR CODE xx ON RBM WRITE
Error code xx has been received whi Ie attempting to write RBM.
ERROR CODE xx ON RBM READ
Error code xx has been received while attempting to read RBM.
t See Tables 9 and 10 of the RBM RT and BP Reference Manual for an explanation of error codes xx.
Table 17. REPLACE Operator Messages
Message
Action
! !AFTER WAIT SET PROTECT SWITCH TO IOFFI, INT. AND KEY-IN lSI
Operator must fo lIow the instructions or
! !BEGIN WAIT
the message will reappea r •
! !AFTER WAIT SET PROTECT SWITCH TO ION I , INT. AND KEY-IN lSI
Operator must follow the instructions or
!
!
BEGIN WAIT
the message wi II reappear.
Note: If the PROTECT switch on the console is set to the OFF position prior to running the job, neither of the above
messages wi II be output.