Command/Response Reference
Program Example
Execute
condition
0000
A202
00
00
(Continued next page)
@MOV(21)
# 0008
D00000
@MOV(21)
# 00CC
D00001
@MOV(21)
# 0000
D00002
@MOV(21)
# 0200
D00003
@MOV(21)
# 0002
D00004
@MOV(21)
# 0000
D00005
• Receives a transparent frame just once when the
Network Communications Port Enabled Flag for
port 1 and the execute condition (CIO 000000)
turn ON.
• Creates control data starting at D00000.
Word
Content
D00000
00
08
Command data length = 8
bytes
D00001
00
CC
Response data length = 204
bytes
D00002
00
00
Target network address = 0
D00003
02
00
Target node address = 2
Target node number address
= 0
D00004
00
02
Response required
Communications port No. = 0
Retries = 2
D00005
00
00
Response monitoring time =
2 s
Section 7-5