XIII - Alarm messages

By default, the alarm configuration is :
- Activated: if an alarm is present, a message is displayed on the readout,
- Alarm relay: relay 3 is activated if an alarm is triggered.
- E-mail: the Sigma sends an e-mail (see messaging programming in the PC software),
- SNMP: the SNMP server will receive a message (trap).
If the display of alarms was selected by the installer at the time of configuration of the unit (See
11.4 Alarm configuration, page 31), the master clock can display alarm messages :
If an alarm is active, the display alternates between the
date and the alarm message.
Press the
key to view additional information on this
alarm.
Example :
If several alarms are active simultaneously, the display is:
Press the
key to view the additional information.
Press the
key to view the following alarms.
The alarms are displayed in chronological order.
To acknowledge an alarm, press the
Alarm activation is immediate for all alarms, except for the
synchronisation alarms for which the activation times are as follows :
- Absence of NTP synchronisation: 3 hours,
- Absence of DCF or GPS synchronisation: 24 hours.
In the Auto mode, if there is no synchronisation from the primary source for more than 2h30, the
Sigma switches to the next source and if there is still no synchronisation after 30 minutes then the
Sigma activates the alarm.
10:54.32
Alarm :output 01
Overload on 01
08/09/14 10:54.32 ok