Factory Setting Restoration Menu - Bodet Sigma C Installation And Operating Instructions Manual

Master clock
Table of Contents

Advertisement

11.9 Factory setting restoration menu

This menu can be used to reinstall the initial factory setting.
To go to this master clock menu, validate the option in the
technician menu with the
The following screen is displayed :
To reinstall the factory configuration, validate with the
key.
XII - Priority of execution of programs
Circuit 1 in alarm, circuits 2 and 3 in time distribution (D1D2 tower
clock)
Manual control of relays
Manual selection of a particular day (bank holiday / day before bank
holiday / special day)
Programmed special day
Programmed holidays and bank holidays
Weekly program
When the master clock is configured in one of the modes, all the program steps of the lower-
priority modes are ignored.
The "astronomical" and "periodic" modes, which are accessible only via software programming
on a PC, do not have high priority (the astronomical, periodic and weekly modes, which will
rarely be programmed together on the same circuit, are lumped together at low level).
34
key.
Function
Factory config.
Restore config : No
factory configuration ok
ok
õ
ú
Priority
1 (high)
2
3
4
5
6 (low)