Cisco ONS 15454 Series Reference Manual page 56

Multiservice provisioning platforms; shelf and backplane hardware
Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

ONS_15454_Reference_Manual_R8.5.x_--_Shelf_and_Backplane_Hardware
Card Slot Requirements
The ONS 15454 shelf assembly has 17 card slots numbered sequentially from left to right. Slots 1 to 6 and 12
to 17 are multiservice slots that are used for electrical, optical, and Ethernet cards (traffic cards). Card
compatibility depends on the EIA, protection scheme, and cross-connect card type used in the shelf. Refer to
the Card Compatibility for more detailed compatibility information.
Slots 7 and 11 are dedicated to TCC2/TCC2P cards. Slots 8 and 10 are dedicated to cross-connect (XCVT,
XC10G, and XC-VXC-10G) cards. Slot 9 is reserved for the optional AIC-I card. Slots 3 and 15 can also
host electrical cards that are used for 1:N protection. (See the Electrical Card Protection for a list of electrical
cards that can operate as protect cards.)
Caution! Do not operate the ONS 15454 with a single TCC2/TCC2P card or a single
XCVT/XC10G/XC-VXC-10G card installed. Always operate the shelf assembly with one working and one
protect card of the same type.
Shelf assembly slots have symbols indicating the type of cards that you can install in them. Each ONS 15454
card has a corresponding symbol. The symbol on the card must match the symbol on the slot.
Table 1-29 shows the slot and card symbol definitions.
Note: Protection schemes and EIA types can affect slot compatibility.
Table 1-29: Slot and Card Symbols
Symbol
Color/Shape
Slots 1 to 6 and 12 to 17. Only install ONS 15454 cards with a circle symbol on the
Orange/Circle
faceplate.
Slots 5, 6, 12, and 13. Only install ONS 15454 cards with circle or a triangle symbol on
Blue/Triangle
the faceplate.
TCC2/TCC2P slot, Slots 7 and 11. Only install ONS 15454 cards with a square symbol
Purple/Square
on the faceplate.
Cross-connect (XCVT/XC10G) slot, Slots 8 and 10. Only install ONS 15454 cards with
Green/Cross
a cross symbol on the faceplate.
Red/P
Protection slot in 1:N protection schemes.
AIC-I slot (Slot 9). Only install ONS 15454 cards with a diamond symbol on the
Red/Diamond
faceplate.
Slots 1 to 4 and 14 to 17. Only install ONS 15454 cards with a star symbol on the
Gold/Star
faceplate.
(Only used with the 15454-SA-HD shelf assembly) Slots 3 and 15. Only install ONS
Blue/Hexagon
15454 cards with a blue hexagon symbol on the faceplate.
Table 1-30 lists the number of ports, line rates, connector options, and connector locations for ONS 15454
optical and electrical cards.
Table 1-30: Card Ports, Line Rates, and Connectors
Card
DS1-14
Card Slot Requirements
Ports
Line Rate per Port Connector Types
14
1.544 Mbps
Definition
SMB w/wire wrap
adapter, AMP Champ
Connector
Location
Backplane
56