Cisco ONS 15454 Series Reference Manual page 33

Multiservice provisioning platforms; shelf and backplane hardware
Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

ONS_15454_Reference_Manual_R8.5.x_--_Shelf_and_Backplane_Hardware
DS-1
1-14 -
17
DS-3
1-12 -
DS-1
-
16
DS-3
-
DS-1
-
15
DS-3
-
DS-1
-
14
DS-3
-
DS-1
-
13
DS-3
-
DS-1
-
12
DS-3
-
Tables 1-13 and 1-14 show the J-labeling and corresponding card ports for a shelf assembly configured with
high-density 48-port DS-3/EC-1 or 56-port DS-1 electrical cards.
Table 1-13: J-Labeling Port Assignments for a Shelf Configured with High-Density Electrical Cards (A Side)
Slot Port Type TX J4
RX J12
Ports Ports Ports Ports Ports Ports Ports Ports
DS-1
1-14 15-28 29-42 43-56 -
1
DS-3
1-12 13-24 25-36 37-48 -
DS-1
-
2
DS-3
-
Table 1-14: J-Labeling Port Assignments for a Shelf Configured with High-Density Electrical Cards (B Side)
Slot Port Type TX J20
RX J28
Ports Ports Ports Ports Ports Ports Ports Ports
DS-1
1-14 15-28 29-42 43-56 -
17
DS-3
1-12 13-24 25-36 37-48 -
DS-1
-
16
DS-3
-
If you are installing UBIC-H EIAs after the shelf assembly is installed, plug the UBIC-H EIA into the
backplane. The UBIC-H backplane must replace the standard sheet metal cover to provide access to the cable
connectors. The UBIC-H sheet metal covers use the same screw holes as the standard sheet metal covers, but
they have 12 additional holes for panhead screws and three holes for jack screws so you can screw down the
cover and the board using standoffs on the UBIC-H board.
When installed with the standard door and cabling on the backplane, the ONS 15454 shelf measures
approximately 14.5 inches deep when fully populated with backplane cables, and 15.0 inches deep with the
rear cover installed. When installed with the deep door and cabling on the backplane, the ONS 15454 shelf
measures approximately 16.5 inches deep when fully populated with backplane cables, and 17.0 inches deep
with the rear cover installed.
The UBIC-H EIA supports the following cards:
DS1-14, DS1N-14
Table 1-12: J-Labeling Port Assignments for a Shelf Assembly Configured with Low-Density Electrical Cards (B
-
-
-
-
-
-
-
-
-
1-14 -
-
-
-
1-12 -
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1-14 -
-
-
1-12 -
-
-
-
1-14 -
-
-
1-12 -
-
J3
J2
J1
J5
J11
J10
J9
J13
-
-
-
1-14 15-28 29-42 43-56
-
-
-
1-12 13-24 25-36 37-48
J19
J18
J17
J21
J27
J26
J25
J29
-
-
-
1-14 15-28 29-42 43-56
-
-
-
1-12 13-24 25-36 37-48
-
-
-
-
-
-
-
-
-
-
-
1-14 -
-
1-12 -
1-14 -
-
1-12 -
-
-
-
-
-
-
-
-
-
-
-
-
-
J6
J7
J8
J14
J15
J16
-
-
-
-
-
-
J22
J23
J24
J30
J31
J32
-
-
-
-
-
-
33

Advertisement

Table of Contents
loading

Table of Contents