Each AEP alarm input port has provisionable label and severity. The alarm inputs have optocoupler isolation.
They have one common 48-VDC output and a maximum of 2 mA per input. Each opto metal oxide
semiconductor (MOS) alarm output can operate by definable alarm condition, a maximum open circuit
voltage of 60 VDC, anda maximum current of 100 mA. See the External Alarms and Controls for further
information.

Wire-Wrap and Pin Connections

Figure 1-33 shows the wire-wrapping connections on the backplane.
Figure 1-33: AEP Wire-Wrap Connections to Backplane Pins
Table 1-22 shows the backplane pin assignments and corresponding signals on the AIC-I and AEP.
Table 1-22: Pin Assignments for the AEP
AEP Cable Wire Backplane Pin AIC-I Signal AEP Signal
Black
A1
White
A2
Slate
A3
Violet
A4
Blue
A5
Green
A6
Yellow
A7
Figure 1-32: AEP Block Diagram
GND
AEP_GND
AE_+5
AEP_+5
VBAT-
VBAT-
VB+
VB+
AE_CLK_P
AE_CLK_P
AE_CLK_N
AE_CLK_N
AE_DIN_P
AE_DOUT_P