ONS_15454_Reference_Manual_R8.5.x_--_Shelf_and_Backplane_Hardware
23-inch (584.2 mm) rack, two additional inches (50.8 mm) of cable management area is available on each
side of the shelf assembly.
Alarm Expansion Panel
The optional ONS 15454 alarm expansion panel (AEP) can be used with the Alarm Interface
Controller-International card (AIC-I) card to provide an additional 48 dry alarm contacts for the ONS 15454,
32 of which are inputs and 16 are outputs. The AEP is a printed circuit board assembly that is installed on the
backplane. Figure 1-31 shows the AEP board; the left connector is the input connector and the right
connector is the output connector.
The AIC-I without an AEP already contains direct alarm contacts. These direct AIC-I alarm contacts are
routed through the backplane to wire-wrap pins accessible from the back of the shelf. If you install an AEP,
you cannot use the alarm contacts on the wire-wrap pins. For further information about the AIC-I, see the
AIC-I Card.
Figure 1-31: AEP Printed Circuit Board Assembly
Figure 1-32 shows the AEP block diagram.
Figure 1-32: AEP Block Diagram
AMP Champ Cable Management
43