Electrical Interface Assemblies - Cisco ONS 15454 Series Reference Manual

Multiservice provisioning platforms; shelf and backplane hardware
Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

ONS_15454_Reference_Manual_R8.5.x_--_Shelf_and_Backplane_Hardware
forth). As you face the rear of the ONS 15454 shelf assembly, the right side is the A side and the left side is
the B side. The top of the EIA connector columns are labeled with the corresponding slot number, and EIA
connector pairs are marked transmit (Tx) and receive (Rx) to correspond to transmit and receive cables.
Note: For information about EIA types, protection schemes, and card slots, see Card Protection.
EIA Installation
Optional EIA backplane covers are typically preinstalled when ordered with the ONS 15454. A minimal
amount of assembly might be required when EIAs are ordered separately from the ONS 15454. If you are
installing EIAs after the shelf assembly is installed, plug the EIA into the backplane. The EIA has six
electrical connectors that plug into six corresponding backplane connectors. The EIA backplane must replace
the standard sheet metal cover to provide access to the coaxial cable connectors. The EIA sheet metal covers
use the same screw holes as the solid backplane panels, but they have 12 additional 6-32 x 1/2 inch Phillips
screw holes so you can screw down the cover and the board using standoffs on the EIA board.
When using the RG-179 coaxial cable on an EIA, the maximum distance available (122 feet [37 meters]) is
less than the maximum distance available with standard RG-59 (734A) cable (306 feet [93 meters]). The
maximum distance when using the RG-59 (734A) cable is 450 feet (137 meters). The shorter maximum
distance available with the RG179 is due to a higher attenuation rate for the thinner cable. Attenuation rates
are calculated using a DS-3 signal:
For RG-179, the attenuation rate is 59 dB/kft at 22 MHz.
For RG-59 (734A) the attenuation rate is 11.6 dB/kft at 22 MHz.
EIA Configurations
Table 1-1 shows the EIA types supported only by ONS 15454 shelf assembly 15454-SA-ANSI.
Table 1-1: EIA Types Compatible with the 15454-SA-ANSI Only
EIA
Cards
Type
Supported
DS-3
24 pairs of
BNC
DS3XM-6
BNC
EC-1
connectors
High-
DS-3
48 pairs of
Density
DS3XM-6
BNC
BNC
EC-1
connectors
SMB
DS-1
84 pairs of
SMB
DS-3
connectors
EC-1
DS3XM-6

Electrical Interface Assemblies

A-Side
A-Side
Columns
Hosts
Map to
Slot 2
15454-EIA-BNC-A24=
Slot 4
Slot 1
Slot 2
15454-EIA-BNC-A48=
Slot 4
Slot 5
Slot 1
15454-EIA-SMB-A84= 84 pairs of
Slot 2
Slot 3
Slot 4
A-Side Product
B-Side
Number
Hosts
24 pairs of
BNC
connectors
48 pairs of
BNC
connectors
SMB
connectors
B-Side
B-Side Product
Columns
Number
Map to
Slot 14
15454-EIA-BNC-B24=
Slot 16
Slot 13
Slot 14
15454-EIA-BNC-B48=
Slot 16
Slot 17
Slot 12
15454-EIA-SMB-B84=
Slot 13
Slot 14
Slot 15