Carrier 58MSA040-08 Installation, Start-Up, And Operating Instructions Manual page 9

4-way multipoise fixed-capacity condensing gas furnace

Advertisement

-->
To relocate
condensate
trap
fi'om
the blower
shelf
to desired
location,
perfbrm
the following:
1. Remove
3 tubes connected
to condensate
t_ap
2. Remove
trap from blower
shelf by gently pushing
tabs inward
and rotating
t_ap.
3. Install
casing
hole filler
cap (*hctow-supplied
in loose parts
bag) into blower
shelf
hole where
trap was removed.
CARBON
MONOXIDE
POISONING
HAZARD
Failure
to fbllow
this warning
could result
in personal
in}ury
or death.
Casing
hole filler
cap must be installed
in blower
shelf
hole
when
condensate
trap is relocated.
4. Install
condensate
trap into desired
casing
hole by inserting
tube connection
stubs
through
casing
hole and rotating
until
tabs snap into locking
position.
5. Fill unused
condensate
trap casing
holes
with
plastic
filler
caps (*i_ctory=supplied
in loose parts bag)
CONDENSATE
TRAP
TUBING
NOTE:
See Fig 8 or 9 or robe routing
label on main furnace
door
to check
fbr proper
connections.
1. Collector
Box Drain Tube
a Remove
fimtory=installed
plug fi'om LOWER
collector
box
drain robe (blue
and white
striped
label).
b. Install
removed
clamp and plug into [PPER
collector
box
&ain robe (blue label) which
was connected
to condensate
tlap.
c. Connect
LOWER
collector
box drain
connection
to con=
densate
trap.
(1.) Condensate
Trap Located
on Left Side of Casing
Ca3 Connect
LOWER
collector
box &ain
robe (blue
and white
striped
label) to condensate
tlap. Tube
does not need to be cut.
(b.) Clamp
tube to prevent
any condensate
leakage.
(2.) Condensate
Trap Located
on Right
Side of Casing
Ca3 Install
drain
robe
coupling
(fhctow-supplied
in
loose
parts
bag)
into
collector
box
drain
robe
(blue
and white
striped
label) which
was previ=
ously plugged.
(b.) Connect
larger
diameter
&ain
robe
(_tctory°
supplied
in loose
parts
bag)
to &ain
tube cou°
piing,
extending
collector
box
drain
robe
for
connection
to condensate
trap.
(c.)
Route extended
collector
box drain robe between
gas valve and inlet housing
as shown
in Fig. 9.
(d.) Determine
appropriate
length
and cut.
(e.)
Connect
to condensate
trap.
(f.) Clamp
robe to prevent
any condensate
leakage.
2. Inducer
Housing
Drain
Tube
a Remove
fhctoEyoinstalled
cap and
clamp
from
LOWER
inducer
housing
drain connection.
b. Remove
and
discard
UPPER
(molded)
inducer
housing
&ain robe which
was previously
connected
to condensate
t_ap.
c Install
cap and clamp
on UPPER
inducer
housing
&ain
connection
where
molded
&ain robe was removed.
d. l_se inducer housing &ain robe (violet label and factoQ-
supplied in loose parts bag) to connect LOWER inducer
housing drain connection to the condensate
trap.
e. Connect inducer housing drain connection to condensate
trap.
(10 Condensate Trap Located on Left Side of Casing
Ca,) Determine appropriate length and cut,
(b.) Connect tube to condensate trap.
(c.) Clamp robe to prevent any condensate teakage
(20 Condensate Trap Located on Right Side of Casing
Ca.) Route inducer housing drain tube (violet 1abel)
between gas valve and inlet housing behind col-
lector box drain tube
(b) Determine appropriate length and cut
(c.) Connect robe to condensate trap.
(d) Clamp robe to prevent any condensate teakage.
3 Relief Port Tube
Refkr to Pressure
Switch Tubing
section fbr connection
procedure
CONDENSATE
TRAP FIELD DRAIN ATTACHMENT
Refer to Condensate
Drain section fbr recommendations
and
procedures,
PRESSURE
SWITCH
TUBING
One collector
box pressure
tube (pink label) is factory connected
to
the pressure
switch
fbr use when furnace
is installed
in UPFLOW
applications.
This
robe MUST
be disconnected
and used
for the
condensate
trap relief port robe. The other
collector
box pressure
robe (green
label) which
was f_ctory
connected
to the condensate
trap relief
port connection
MUST
be connected
to the pressure
switch
in DOVv_TLOW
or HORIZONTAL
RIGHT
applications.
NOTE:
See Fig. 8 or 9 or robe routing
label on main fhrnace
door
to check
fbr proper
connections
Relocate
robes as described
below.
1. Disconnect
collector
box pressure
robe (pink label) attached
to
pressure
switch
2. Use smaller
diameter
robe
(factor-supplied
in loose
parts
bag) to extend
collector
box pressure
tube (green label) which
was
previously
connected
to
condensate
t_ap
relief
port
connection.
3. Connect
collector
box pressure
robe (green
label) to pressure
switch
connection
labeled
"collector
box."
4. Use
remaining
smaller
diameter
robe
(factmT-supplied
in
loose parts
bag) to extend
collector
box pressure
robe (pink
label) which
was previously
connected
to pressure
switch.
5. Route this extended
tube (pink label) to condensate
trap relief
port connection.
6. Determine
appropriate
length,
cut, and connect
robe.
7. Clamp
robe to relief port connection.
CONDENSATE
TRAP
FREEZE
PROTECTION
Refer
to Condensate
Drain
Protection
section
for recommenda-
tions and procedures
Step
4--Horizontal
Left (Supply-Air
Discharge)
Applications
A horizontal
left fhrnace
application
is where
fhrnace
blower
is
located
to the right of combustion
and controls
section of' furnace,
and conditioned
air is discharged
to the left.