Download Print this page
Carrier 58MSA040-08 Installation, Start-Up, And Operating Instructions Manual

Carrier 58MSA040-08 Installation, Start-Up, And Operating Instructions Manual

4-way multipoise fixed-capacity condensing gas furnace

Advertisement

Quick Links

88MSA
4-Way
MuMtipoise
Fixed-Capacity
Condensing
Gas Furnace
\isit _ v_w carrier.corn
Installation, Start-Up,
and Operating
For Sizes 040--120
Series t50
HEATUNG
& COOUNG
I mlCI[NCY
A93040
NOTE:
Read the entire instl_action manual be%re starting the
installation
This symbol --> indicates a change since the last issue,
Index
Page
DIMENSIONAL
DRAWING
3
SAFETY CONSIDERATIONS
2
(learances
to ( ombustibles
4
CODES AND STANDARDS ........................................................
5
ELE< TROSTATIC DIS<HARGE
(ESD) PRE(AUTIONS
........ 5
INTRODU< TION ..........................................................................
5
APPLICATIONS .....................................
6
General ...........................................
6
[pflow
Applications ...............................
6
Downflow Applications .............................
8
Horizontal Lek (Supply-Air Dischmge) Applications .......
9
Horizontal Right {Supply-Air Discharge) Applications ..... 11
LO< ATION ........................................
13
Gene*al ..........................................
13
Furnace Location Relative to ( ooling Equipment .........
I4
Hazardous Locations ..............................
14
AIR FOR COMBUSTION
AND VENTILATION
..........
14
INSTALLATION ........................................
18
Leveling Legs (If"Desired) ..............................
18
Installation in Upflow and Downflow Applications .........
18
Installation In Horizontal Applications ..................
18
Air Ducts .......................................
! 8
General ........................................
18
Ductwork Acoustical Treatment ....................
20
Supply Air Connections .........................
20
Return Air Connections ..........................
20
Filter Arrangement ................................
20
Bottom Closure Panel ............................
21
Gas Piping .......................................
22
Electrical ( onnections .............................
23
115-v Wiring ...................................
23
24-v Wiring ....................................
24
Accessories ..................................
24
Venting ............................................
27
Removal of Existing Furnaces from
( ommon Vent Systems ..........................
27
Combustion-Air
and Vent Piping ...................
28
Vent Te*mination ..............................
35
Multiventing .................................
35
As an FNFR(JY
ST4Rx¢
Pa_ner
Carrier
Corpora-
tion has
determined
that
this pro_tct
meets the EN'-
FRGY S fARaV g/iidelines
_r energy efflc{ency
I$O 9001:2000
@
AIRFLOW
42>
r
¢
_
HORLIZOTNTA _
_
_
HO _II_C_NTALN'NI 0
AIRFLOW
AIRFLOW
©
AIRFLOW
A93041
Fig. 1--NuRipoise
Orientations
Condensate Drain ....................................................................
35
General .......................................
35
Application .......................................
35
Condensate Drain Protection ......................
36
START°UP, ADJL STMENTS AND SAFETY (HECK .......
37
General ..........................................
37
Prime ( ondensate Trap With Warm ....................
37
Purge Gas Lines ...................................
38
Sequence of Operation .............................
38
Heating Mode .................................
38
Cooling Mode ................................
38
Continuous Blowe* Mode ........................
38
Heat Pump Mode ..............................
39
Component Test ...............................
39
Adjustments .......................................
39
Set Gas Input Rate ..............................
39
Set Temperature Rise ................................
44
Blower Off"Delay (Heat Mode) ....................
44
Set Thermostat Heat Anticipator ....................
45
Manufacturer
reserves
the right
to discontinue,
or change
at any time, specifications
or designs
without
notice
and without
incurring obligations.
PC 101
Catalog No
535-80154
Printed in U.S.A.
Form 58MSA-11SI
Pg 1
2-05
Replaces:
58MSA-10SI

Advertisement

loading