Carrier 58MSA040-08 Installation, Start-Up, And Operating Instructions Manual page 24

4-way multipoise fixed-capacity condensing gas furnace

Advertisement

Table 7--Approved
ASTM SPECBFJOATION
(MARKED
ON MATER_AL)
D1527
D1788
D2235
D2241
D2466
D2468
D2564
D2881
D2665
Combustion-Air
and Vent Pipe, Fitting and Cement Materials
MATERIAL
PiPE
FITTINGS
ABS
Pipe
--
PVC
Pipe
--
For ABS
--
--
PVC
Pipe
--
PVC
--
Fittings
ABS
--
Fittings
For PVC
--
--
ABS
Pipe
Fittings
PVC
Pipe
Fittings
SOLVENT
CEMENT AND PRBMI=RS
Solvent
Cement
Solvent
Cement
DESCRIPTBON
Schedule-40
Schedule-40
For ABS
SDR-21 & SDR-26
Schedule-40
Schedule-40
For PVC
DWV at Schedule-40
tPS sizes
DWV
F438
F441
F442
F493
F628
F656
F891
CPVC
--
Fittings
CPVC
Pipe
--
CPVC
Pipe
--
For CPVC
--
--
ABS
Pipe
--
For PVC
--
--
PVC
Pipe
--
Solvent
Cement
Primer
Schedule-40
Schedule-40
SDR
For CPVC
Cellular Core DWV at Schedule-40
IPS sizes
For PVC
Cettular Core Schedule-40
& DWV
NOTE:
Proper
polarity
must
be maintained
for 115-v wiring
If
polarity
is incorrect,
control
center
fault code indicator
light will
flash rapidly
and Alrnace will NOT
operate.
FIRE
HAZARD
Failure
to %11ow this warning
could
result
in serious
injury,
death, or property
damage.
Do not connect
aluminum
wire
between
disconnect
switch
and furnace.
Use only copper
wire. (See Fig. 29.)
ELECTRIC
DISCONNECT
SWITCH
A93033
Fig. 29--Disconnect
Switch
and Furnace
ELECTRICAL
SHOCK
AND
FIRE
HAZARD
Failure
to fbllow
this warning
could
result
in serious
inju W,
death, or property
damage.
The cabinet MUST
have an unintemlpted
or unbroken
ground
according
to NEC ANSI
NFPA 70-2002
and Canadian
Elec=
trical (7ode CSA
C22.1
or local codes to minimize
personal
injury if an electrical
fimlt should
occur. This may consist
of
electrical
wire or conduit
approved
for electrical
ground
when
installed
in accordance
with existing
electrical
codes. Do not
use gas piping
as an electrical
ground.
J-Box Relocation
1. Remove 2 screws holding auxiliaQ' J-box. (See Fig 31.)
2. Rotate J=box 180 ° and attach box to leit side, using holes
provided.
24
ELECTRICAL
SHOCK
AND FIRE
HAZARD
Failure
to follow
this warning
may result
in serious
inju W,
death,
or property
damage,
If manual
disconnect
switch
is to be mounted
on furnace,
select
a location
where
a drill or fhstener
will not contact
electrical
or gas components.
24-V WIRING
Make field 24-v thermostat connections at 24-v terminal block on
fm'nace control
For proper
cooling operation,
Y wire from
thermostat MUST be connected to ¥ terminal on filrnace connol,
as shown in Fig. 30. The 24=v terminal block is marked fbr easy
connection of field wiring. (See Fig. 320 The 24=v circuit contains
a 3=amp, automotive4ype
fuse located on fi/mace control. (See
Fig. 33.) Any electrical shorts of 24-v wiring during installation,
service, or maintenance may cause lime to blow. If filse replace-
merit is required, use only a time of identical size (3 amp) and type.
The control will flash code 24 when fuse needs replacement.
NOTE:
Use AWG No. 18 color-coded copper thermostat wire fbr
lengths up to 100 it. For wire lengths over 100 ft, use AWG No.
16 wire.
A( CESSORIES
l. Electronic Air Cleaner (EAC)
Two quick-connect
terminals marked EAC-I and EAC°2 are
provided for EAC connection. (See Fig 33) These terminals
are energized with 115v (1 0-amp maximum) during blower
motor operation.
NOTE:
DO NOT connect f:urnace control HI_M tem_inal to HUM
(humidifier) terminal on Thermidistat-f_L Zone Controller or simi-
tar device
See Thermidistat
TM,
Zone Controller, thermostat, or
controller manufi_cturer's instructions fbr proper connection.