4-way multipoise fixed-capacity condensing gas furnace

Advertisement

Step
3--Purge
Gas Lines
FIRE
AND EXPLOSION
HAZARD
Failure to %llow
this warning
could result in a fire, explosion,
personal
injury,
or death
Never
purge a gas line into a combustion
chamber.
Never
test
for
gas
leaks
with
an
open
flame.
Use
a commercially
available
soap solution
made
specifically
for the detection
of
leaks to check
all connections.
[f not previously
done, purge
lines after all connections
have been
made
and check
for leaks.
Step
4--Sequence
of Operation
FURNA(E
MAY
NOT
OPERATE
Failure
to %llow
this caution
may result in t:urnace operation
stopping
and water
pipes freezing
during
cold weather.
Furnace
control
must
be grounded
for proper
operation,
or
control
will
lock
out.
Control
is
grounded
through
green/yellow
wire routed
to gas valve and burner
box screw
[sing
the schematic
diagram
in Fig. 32, fbllow
the sequence
of
operation
through
the diffkrent
modes
Read and fbltow
the wiring
diagram
very- carefully.
NOTE:
If a power
interalpfion
occurs
during
a call for heat (W),
the
control
will start
a 90-second
blower-only
ON period
two
seconds
after power
is restored,
if the thermostat
is still calling
for
gas heating.
The red LED
light
will flash
code
12 during
the
90-second
period,
after which
the LED will be ON continuous,
as
long
as no faults
are detected.
Afier
the 90-second
period,
the
flul_ace will respond
to the thermostat
normally
The blower
door
must
be installed
for power
to be condtlcted
through
the
blower
door
interlock
switch
ILK to the
furnace
control
(PU,
transl\_rmer
TRAN,
inducer
motor
IDM,
blower
motor
BLWM,
hot-surface
igniter
HSI, and gas valve
GV.
1. Heating
(See Fig
30 fbr thermostat
connections.)
The wall
thermostat
"calls
for heat",
closing
the R to W
circuit.
The fl/mace
contlol
perfbm_s
a self-check,
verifies
the
pressure
switch
contacts
PRS are open, and starts the inducer
motor
IDM.
a. Inducer
Prepurge
Period-
As the
inducer
motor
IDM
comes up to speed, the pressure
switch
contacts
PRS close,
24 vac power
is supplied
fbr a field installed
humidifier
at
the
HUM
terminal
and
the control
begins
a 15-second
prepurge
period.
b. Igniter
Warm-Up-
At tl-_eend of the prepurge
period,
the
Hot-Surfi_ce
Igniter
HSI
is energized
fbr
a 17-second
igniter
warm-up
period.
c. Trial-Nr-Ignition
Sequence-
When
the igniter
warm-up
period is completed,
the main gas valve relay contacts
GVR
close
to energize
the gas valve
GV, the gas valve
opens.
The gas valve GV pemaits
gas flow to the burners
where
it
is ignited
by the Hot Surfhce Igniter HSL Five seconds
after
the GVR closes,
a 2-second
flame period begins.
The HSI
igniter
will remain
energized
until d-_e flame
is sensed
or
until the 2-second
flame proving
period
begins.
d. Flame-Proving-
When
the burner
flame
is proved
at the
flame-proving
sensor
electrode
FSE,
the fl/mace
contlol
CPU begins
the blower-ON
delay period
and continues
to
hold the gas valve
GV open.
If the burner
flame
is not
38
proved
within
two seconds,
the control
CPU will close the
gas valve GV, and the control
CPU will repeat the ignition
sequence
fbr up to three
more
Trials-For-Ignition
befbre
going
to Ignition-Lockout.
Lockout
will be
reset
auto-
matically
after three
hours,
by momentarily
interrupting
115 vac power
to the furnace,
or by interrupting
24 vac
power
at SEC1 or SE(2
to the [:urnace control
CPU (not at
W, G, R, etc.)
If flame
is proved
when
flame
should
not be present,
the
fhmace
control
CPU
will lock out of Gas-Heating
mode
and operate
the inducer
motor IDM until flame is no longer
proved.
e. Blower-On
Delay-
If the burner
flame
is proven,
the
blower
motor is energized
on HEAT speed 66 seconds
after
the gas valve
GV is energized.
Simultaneously,
the electronic
air cleaner
terminal
EAC-!
is energized
and remains
energized
as tong as the blower
motor
BLWM
is energized.
f_ Blower-Off
Delay-
When
the thermostat
is satisfied,
the
R-to-W
circuit
is opened,
de-energizing
the gas valve GV,
stopping
gas flow
to the burclers,
and de-energizing
the
humidifier
terminal
HLM.
The inducer
motor
IDM
will
remain
energized
for a 15-second
post=purge
period.
The
blower
motor BLWM
and air cleaner
terminal
EAC-I
wilt
remain
energized
fbr 90, 120, 150, or 180 seconds
(depend-
ing
on
the
blower-OFF
delay
selection).
The
flu'hate
control
CPU
is fitctory-set
for a 120-second
blower-OFF
delay.
Cooliug
Mode
(See Fig. 30 fbr them_ostat
connections)
The thermostat
closes the R-to-G-and-Y
circuits.
The R-to-Y
circuit
starts the outdoor
unit,
and the R-to-G
and Y circuits
start the t\lrnace
blower
motor
BLWM
on COOL
speed.
The electronic
air cleaner
terminal
EAC-1
is energized
with
115 vac when the blower
motor BLWM
is operating.
When the thermostat
is satisfied,
the R-to-G-and-Y
circuits
are
opened.
The outdoor
unit will stop,
and the t\trnace
blower
motor BLWM
will continue
operating
on the COOL
speed fbr
an additional
90 seconds.
Cut jumper
J2 to reduce the cooling
off'delay
to 5 seconds.
(See Fig. 33.)
Continuous
Blower
Mode
When
the
R-to-G
circuit
is closed
by the
themlostat,
the
blower
motor
BLWM
will
operate
on continuous-blower
speed (same as HEAT speed)
Terminal
EAC-!
is energized
as
long as ff*e blower
motor
BLWM
is energized
During
% call for heat('
the blower
BLWM
will stop during
igniter
wam_-up
(17
seconds),
ignition
(7 seconds),
and
blower-ON
delay
(65
seconds),
allowing
the
fhmace
heat
exchangers
to heat up more quickly,
then restarts
at the end of
the blower-ON
delay period
at HEAT
speed
In heating,
the furnace
control
CPU will continue
running
the
blower
motor
BLWM
at HEAT
speed
after
the
selected
blower-OFF
delay period
is completed.
When
the
thermostat
"calls
fbr cooling",
the blower
motor
BLWM
will operate
at (OOL
speed.
When
the d_em_ostat
is
satisfied,
the blower
motor BLWM
will operate
an additional
90 seconds
on COOL
speed befbre
reverting
back to HEAT
speed.
Jumper
J2 can be can be cut to reduce
the cooling
offtdelay
to 5 seconds.
(See Fig. 33.)
When the R-to-G
circuit is opened,
the blower
motor BLWM
will continue
operating
for an additional
5 seconds,
if no other
flmction
requires
blower
motor
BLWM
operation.