5.14 Shock Sensor Alarm

Shock sensor alarm is deactivated by default. To activate:
Command:
Response: Shock is activated! e.g.
shock123456
Now when TK102-NANO detects vibration, it will send SMS "Sensor alarm+location" to
authorized numbers.
To cancel shock sensor alarm:
Command: noshock+password e.g.
noshock123456
Shock sensor sensitivity configuration:
The shock sensor module has three different sensitivity settings;
First level: Alarm will be triggered after detecting single vibration.
Command: sensitivity+password+space+1 e.g.
sensitivity123456 1
Second level: Alarm will be triggered after detecting 8 vibrations in 2 seconds.
Command: sensitivity+password+space+2 e.g.
sensitivity123456 2
Third level: Alarm will be triggered after detecting 25 vibrations in 5 seconds.
Command: sensitivity+password+space+3 e.g.
sensitivity123456 3
shock+password
10