Response: tracker ok! e.g.
tracker123456

5.12 Data logging

Auto logging:If the TK102-NANO loses GSM or GPRS signal, it can store the
tracking position and alerts automatically on the flash drive upon the pre-set conditions.
When GSM reception is re-established, all the event alerts will be auto-sent to the authorized
numbers or online tracking server.
Logging at preset intervals:
Command: save030s005n+password
Response: save ok
e.g. save030s005n123456
Once set, TK102-NANO will store the lat, long locations every 30 seconds for 5 times. (S:
second, m: minute; h: hour).
Continuous logging:
Command: save030s***n+ password
Response: save ok
e.g.
save030s***n123456 Logging
Clearance:
Command: clear+ password
Response: clear ok e.g.
clear123456
Logging Volume: Built-in flash 1MB (store about 16,000 positions); This can be
extended by adding a Micro SD card to the slot located under the Sim Card Slot. A 2gb Micro
SD card is sufficient to record location data for up to 10 months.
Data Logging function also enables you to use this tracker as a GPS Logger. . You can
download the location data to your pc by using the free PC Software provided through USB
connection.