[8] ADJUSTMENTS
MX-FN10
1. Finisher/saddle unit and Punch unit
1)
Select "FINISHER ADJUSTMENT" in SIM 3-10.
2)
Select a setup item and change the setup value.
SIMULATION NO.03-10
TEST
FINISHER ADJUSTMENT
A
:
50
:
SADDLE POSITION
A
50
B
:
50
:
FOLDING POSITION
C
:
50
:
FRONT ADJUST
D
:
50
:
REAR ADJUST
E
:
50
:
STAPLE REAR
F
:
50
:
STAPLE REAR R
G
:
50
:
STAPLE FRONT
H
:
50
:
STAPLE FRONT R
I
:
50
:
STAPLE BOTH
J
:
50
:
STAPLE PITCH
K
:
50
:
PUNCH CENTER
:
PUNCH HOLE
L
:
50
10 key
SIMULATION NO.03-10
TEST
FINISHER ADJUSTMENT
A
:
30
:
SADDLE POSITION
A
30
B
:
50
:
FOLDING POSITION
C
:
50
:
FRONT ADJUST
D
:
50
:
REAR ADJUST
E
:
50
:
STAPLE REAR
F
:
50
:
STAPLE REAR R
G
:
50
:
STAPLE FRONT
H
:
50
:
STAPLE FRONT R
I
:
50
:
STAPLE BOTH
J
:
50
:
STAPLE PITCH
K
:
50
:
PUNCH CENTER
L
:
50
:
PUNCH HOLE
Adjustable setup range is as follows.
<Set range and default value of each set value>
Item
Display
SADDLE
Saddle binding
A
POSITION
FOLDING
Saddle folding position
B
POSITION
adjustment
FRONT
Alignment position
C
ADJUST
adjustment (Front)
REAR
Alignment position
D
ADJUST
adjustment (Rear)
STAPLE
Staple binding position
E
REAR
adjustment (Rear one
position)
STAPLE
Staple binding position
F
REAR R
adjustment (Rear one
position/ R system)
STAPLE
Staple binding position
G
FRONT
adjustment (Front one
position)
STAPLE
Staple binding position
H
FRONT R
adjustment (Front one
position/ R system)
STAPLE
Staple binding position
I
BOTH
adjustment (Two positions
center)
STAPLE
Staple binding position
J
PITCH
adjustment (Two positions
pitch)
PUNCH
Punch center adjustment
K
CENTER
CLOSE
OK
OK
CLOSE
OK
Set
Item
Default
range
25 - 75
50
25 - 75
50
35 - 65
50
35 - 65
50
25 - 75
50
45 - 75
50
25 - 75
50
25 - 55
50
45 - 55
50
35 - 62
50
35 - 65
50
MX-FN10 ADJUSTMENTS 8 – 1
Service Manual
Item
Display
PUNCH
L
HOLE
SADDLE_A
M
DJUST_
POS
GRIPPER_
N
0
POS
<Amount of change and change direction for each set value>
Item
Display
A
SADDLE
POSITION
B
FOLDING
POSITION
C
FRONT
ADJUST
0
D
REAR
ADJUST
E
STAPLE
REAR
F
STAPLE
REAR R
G
STAPLE
FRONT
H
STAPLE
FRONT R
I
STAPLE
BOTH
Item
range
Punch hole position
30 - 60
adjustment
Saddle alignment position
35 - 65
adjustment
Gripper exit position
35 - 65
adjustment
Item
Change
Change direction
Saddle
0.2mm
Large value: The binding
binding
position is lower than the
center.
Small value: The binding
position is upper than the
center.
Saddle
0.2mm
Large value: The folding
folding
position is lower than the
position
center.
adjustment
Small value: The folding
position is upper than the
center.
Alignment
0.2mm
Large value: The
position
alignment plate position is
adjustment
shifted to the center.
(Front)
Small value: The
alignment plate position is
shifted to the outside.
Alignment
0.2mm
Large value: The
position
alignment plate position is
adjustment
shifted to the center.
(Rear)
Small value: The
alignment plate position is
shifted to the outside.
Staple
0.2mm
Large value: The distance
binding
between the staple
position
position and the paper
adjustment
edge becomes longer.
(Rear one
Small value: The distance
position)
between the staple
position and the paper
edge becomes shorter.
Staple
0.2mm
Large value: The distance
binding
between the staple
position
position and the paper
adjustment
edge becomes longer.
(Rear one
Small value: The distance
position/ R
between the staple
system)
position and the paper
edge becomes shorter.
Staple
0.2mm
Large value: The distance
binding
between the staple
position
position and the paper
adjustment
edge becomes shorter.
(Front one
Small value: The distance
position)
between the staple
position and the paper
edge becomes longer.
Staple
0.2mm
Large value: The distance
binding
between the staple
position
position and the paper
adjustment
edge becomes shorter.
(Front one
Small value: The distance
position/ R
between the staple
system)
position and the paper
edge becomes longer.
Staple
0.2mm
Large value: The staple
binding
position is shifted to the
position
front side from the center.
adjustment
Small value: The staple
(Two
position is shifted to the
positions
rear side from the center.
center)
Set
Default
50
50
50