B. Wiring Requirements - Outdoor Lifestyles ODMEZG-36 Installation Manual

Mezzanine series
Table of Contents

Advertisement

B. Wiring Requirements

Intellifire™ Touch Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire IFT
controlled appliance junction box to a switched circuit. Incor-
rect wiring will override IFT safety lockout.
• Refer to Figure 8.3 or 8.4, IFT Wiring Diagram.
• This appliance is equipped with an Intellifire™ Touch
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
Figure 8.3 IntelliFire™ Touch Wiring Diagram without Power Vent
38
FLAME
SENSE
IFT-RC400
REMOTE
CONTROL
S
RF MODULE
APPLIANCE
ON/OFF
CONTROL
Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
Accessories Requirements
• This appliance ships standard with a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
IGNITER
ADAPTER
I
LIGHTING
HARNESS
6 PIN
BLK
RED
SPLITTER
RED
BLK
BRN
BLK
TO JUNCTION
BOX 110-120
VAC
WIRE HARNESS
LIGHT JOIN
INCANDESANT
LIGHTING
6V DC
BATTERY PACK
RED
BLK

Advertisement