Outdoor Lifestyles ODMEZG-36 Installation Manual

Mezzanine series

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
MEZZANINE
SERIES
Models:
CERTIFIED
S
B
AFETY
ARRIER
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
Installation Manual
Installation and Appliance Setup
Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ODMEZG-36 and is the answer not in the manual?

Questions and answers

Summary of Contents for Outdoor Lifestyles ODMEZG-36

  • Page 1 See Table of Contents for location of additional Commonwealth gases, unless a certified kit is used. of Massachusetts requirements. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 2 J. Vent Diagrams ....... . . 24 Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 3: Installation Standard Work Checklist

    Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective action needed _____________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)  = Contains updated information. 4601-902B 06/17 Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 4: A. Appliance Certification

    Models Maximum Input Size Input BTU/h (U.S. or Canada) BTU/h (DMS) ODMEZG-36 Qty. 2 (0-4500 FT) 34,000 23,000 (NG) ODMEZG-36 Qty. 2 34,000 23,000 (0-4500 FT) (Propane) 1.28 Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 5 VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 6: A. Design And Installation Considerations

    Plumb line Safety glasses Level Reciprocating saw Manometer Flat blade screwdriver 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300ºF minimum continuous exposure rating) Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 7: 3 Framing And Clearances

    Appliance Dimensions Table Location Inches Millimeters Location Inches Millimeters 49-1/8 1248 6-5/8 41-1/2 1029 1-1/2 23-5/8 9-1/8 29-5/8 24-5/8 50-3/4 1289 19-1/8 37-3/4 20-1/8 ► Figure 3.1 Appliance Dimensions Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 8: B. Clearances To Combustibles

    (152 mm) 6” (152 mm) FP2421 Min. Min. From Opening 5-3/4” (146 mm) Min. to Combustibles Figure 3.3 - Ceiling and Sidewall Clearances for Both Sides of Fireplace Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 9: Mantel Clearances

    18-1/8” 51-3/4” Refer to Section 10 for hearth, mantel and wall projection information. 51-3/4” 18-1/8” ► Figure 3.5 Appliance Locations Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 10 If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance. ► Figure 3.6 Clearances to Combustibles Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 11: C. Constructing The Appliance Chase

    Note: Figure 3.5 and Figure 3.6, show the fireplace installed on the floor. However, this fireplace can be elevated off the floor provided that the fireplace is properly supported by framing materials and the ceiling clearances are maintained. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 12: E. Hearth Extension

    Figure 3.8 Non-Combustible Zone 3/4 in. MAX 8 in. BOTTOM OF HEARTH WOOD OR OTHER FIREPLACE COMBUSTIBLE FLOOR REFRACTORY OR PLATFORM Figure 3.7 Fireplace Positioned on Combustible Surface Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 13: A. Securing And Leveling The Appliance

    However, this fireplace can be elevated off the floor provided that the fireplace is properly supported by framing materials and the ceiling clearances are maintained. Figure 4.1 Nailing Tab Locations Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 14: B. Installing Non-Combustible Facing Material

    Figure 4.2 Nailing Tabs Exterior/Outdoor Side Interior Side • Optional: Secure the appliance to the floor by inserting two screws through the pilot holes at the bottom of the appliance. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 15: C. Installation Instructions For Outdoor Side

    3” 3/4 in. 3/4” 3/4” 3/4” 3/4” All edges should be overlapped by a Figure 4.5 minimum of 3/4 in. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 16 NOTE: Seal along Seal along bottom edge and Seal this seam bottom edge boundary of facing with caulk (both with caulk. material with caulk. sides). Figure 4.7 Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 17: A. Vent Termination Minimum Clearances

    Over 20/12 to 21/12 ..........8.0 * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 5.1 Minimum Height From Roof To Lowest Discharge Opening Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 18: B. Chimney Diagram

    2 sides beneath the floor. • Vinyl siding shield is required for use with vinyl siding. Figure 5.3 Minimum Clearances for Termination See Service Parts list for information. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 19: C. How To Use The Vent Graph

    Horizontal dimension from the finished outside wall to the center of the pipe on the fireplace Figure 5.4 Rear Wall Venting Graph (No Horizontal Elbows) FP2132 sidewall vent graph Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 20 ⁄ ’ (5.3 m) and if a 90° elbow is required in the Horizontal run horizontal vent it must be reduced to 14 ⁄ ' (4.4 m). reduction Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 21: E. Below Grade Installations

    #8 x ⁄ " sheet metal screws. It will be necessary to extend vent pipes out as far as the protruding wall face. Figure 5.10 Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 22: G. Approved Pipe

    DO NOT vent to a pipe FP1179 serving a separate solid fuel burning appliance. max bends Max. 10' (3m) Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17 Max. Height 40' (12.2m)
  • Page 23: H. Use Of Elbows

    Figure 5.14 Vertical and Horizontal Offset for DVP and SLP Elbows DVP36 25-1/2 DVP48 1219 DVP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108 DVP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216 Figure 5.13 Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 24: I. Measuring Standards

    (6 mm) MEASURE TO SHADED SURFACE (OUTSIDE MOUNTING SURFACE) Figure 5.17 Figure 5.15 Measure to Outside Mounting Surface Figure 5.16 Measure to Top of Last Section of Pipe Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 25 Unless the Vent pipe clearances vertical run is 7 ⁄ ' or higher from floor of fireplace, the clearance for horizontal run is 1" on all sides. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 26 Note: If installing a vertical vent/termination off the top of the appliance, the optional exhaust restrictor may be needed. Note: Use DVP Series components only. Figure 5.19 Vertical Vent Maximum Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 27 Top Vent - Vertical Termination Venting with 2 elbows WARNING! Risk of Fire! DO NOT attach elbow directly to the appliance. • The ODMEZG-36 requires a minimum of 12 inches of vertical venting before attaching any elbow to the appliance. ODMEZG-36 Minimum Maximum Note: Use DVP Series 1 ft.
  • Page 28 Top Vent - Vertical Termination Venting with 3 elbows WARNING! Risk of Fire! DO NOT attach elbow directly to the appliance. • The ODMEZG-36 requires a minimum of 12 inches of vertical venting before attaching any elbow to the appliance. ODMEZG-36 Minimum Maximum 1 ft.
  • Page 29: A. Pipe Clearances To Combustibles

    * Shows center of vent framing hole for top venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 6.2 Wall Penetration Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 30: C. Install The Ceiling Firestop

    Figure 6.3 Installing Ceiling Firestop INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 6.4 Installing the Attic Shield Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 31: A. Assemble Vent Sections

    Use screws no longer than 1/2 INCORRECT in. (13 mm). If predrilling screw holes, DO NOT penetrate Figure 7.4 Seams inner pipe. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 32: B. Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner flue is not required. • All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 33: D. Disassemble Vent Sections

    Figure 7.10 • Pull carefully to separate the pieces of pipe. Figure 7.9 Rotate Seams for Disassembly Figure 7.10 Align and Disassemble Vent Sections Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 34: E. Vertical Termination Requirements

    • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 7.12. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 35: F. Horizontal Termination Requirements

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be field constructed. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 36 1-1/2 IN. (38 MM) MIN. HEAT SHIELD OVERLAP WALL SHIELD FIRESTOP SLIP SECTION CAN BE EXTENDED INNER VENT SHEATHING OUTER VENT INTERIOR EXTERIOR Figure 7.15 Venting Through the Wall Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 37: A. General Information

    Not Supplied Junction box was installed at the factory. See Figure Junction Box 8.1. Figure 8.2 - Junction Box Wiring Diagram Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 38: B. Wiring Requirements

    RF MODULE LIGHTING HARNESS WIRE HARNESS LIGHT JOIN INCANDESANT LIGHTING 6 PIN 6V DC SPLITTER BATTERY PACK APPLIANCE ON/OFF CONTROL Figure 8.3 IntelliFire™ Touch Wiring Diagram without Power Vent Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 39 BOX 110-120 RF MODULE LIGHTING HARNESS WIRE HARNESS LIGHT JOIN INCANDESANT LIGHTING 6 PIN POWER VENT (OPTIONAL) ACCESSORY CABLE JUMPER WIRE Figure 8.4 IntelliFire™ Touch Wiring Diagram withPower Vent Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 40: A. Fuel Conversion

    1/2 psig. • Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 41: D. Gas Connection

    • Ensure adequate ventilation. • Ensure there are no ignition sources such as sparks or open flames. Figure 9.3 Top Down View of Controls with Screen Barrier and Galss Door Removed Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 42: F. Air Shutter Setting

    NOTICE: If sooting occurs, provide more air by opening to access the air shutter. the air shutter. • Loosen the Philips screw. Air Shutter Settings Propane ODMEZG-36 1/4 IN. No Cap Figure 9.4 Air Shutter Location Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 43: A. Facing And Finishing Instructions

    Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC. WARNING! Risk of Fire! Maintain specified air space clearances to combustibles. Inadequate air space could cause overheating and fire. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 44 Fill, smooth and finish wall and qualifications of non-combustible and combustible joints with chemically setting-type joint compound. It will materials. provide a more crack-resistant joint than air-drying light- weight compound. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 45: B. Glass Frame Removal

    Une barrière visant à réduire le risque de brûlure par le hublot chaude est fournie avec cet appareil et doit être installé. FP2432 open cam levers Figure 10.4 - Remove Glass Frame FP2433 lift glass Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 46: C. Light Installation

    NOTE: Up to three (3) packs of stones may be used. Stones should be placed around, but NEVER direcly on the burner or pilot area, as sooting may occur. Arrange the stones to suit your style. Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 47: Safety Barrier Installation

    être installé. Slot Slots (Qty: 4. Two per side) Figure 10.8 - Screen Slot Placement Figure 10.7 - Barrier Screen Install Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 48: A. Vent Components Diagrams

    (508 MM) 6 in. (152 mm) 14 IN. (356 MM) 12 IN. DVP-WS (Wall Shield Firestop) (305 MM) DVP-RDS ROOF DECK INSULATION SHIELD Figure 11.1 DVP Vent Components Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 49 79 mm 117 mm DVP-TRAP 5-3/8 in. 9-3/8 in. Horizontal Termination Cap Trap2 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 11.2 DVP Vent Components Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 50 13-7/8 in. 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Cap Shield Figure 11.3 DVP Vent Components Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 51 140 mm 213 mm 146 to 213 mm 3° 87° 15 in. (381 mm) 10-1/2 in. 267 mm 10-7/8 in. 276 mm DVP-HRC-SS DVP-HRC-ZC-SS Figure 11.4 DVP Vent Components Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 52 SL-2DVP Adapter Adapter 7-3/8 IN. 187 mm 17-7/8 IN. 454 mm 14 IN. 356 mm 12 IN. 305 mm SLP-TB1 Basement Vent Cap Figure 11.5 PVI-SLP Vent Components Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 53 Use if the PVLP-SLP is installed in a high traffic 100 FT PV Wire Harness PVI-WH100 area. PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 11.6 PVLP-SLP Vent Components Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 54 8-11/16 in. 1-1/2 in. 12 in. 5-1/2 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 12.8 SLP Series Vent Components Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...
  • Page 55: B. Accessories

    Please contact your Outdoor Lifestyles dealer with any questions or concerns. For the location of your nearest Outdoor Lifestyles dealer, please visit www.outdoorlifestylesproducts.com. Printed in U.S.A. - Copyright 2016 Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17...

Table of Contents