E. Chimney Requirements
When planning your fireplace location, the chimney construc-
tion and necessary clearances must be considered. The fire-
place system and chimney components have been tested to
provide flexibility in construction. The following figures are
the minimum distances from the base of the fireplace.
•
Minimum overall straight height is 10 ft If the fireplace is
freestanding and a minimum of 10 ft from a combustible
structure. See Figure 3.2.
• Chimney must extend 2 ft (.6 m) above any portion of
the roof within 10 ft (3048 mm) of the chimney. Refer to
Figure 6.2.
•
MINIMUM HEIGHT WITH OFFSET/RE-
TURN
•
MAXIMUM HEIGHT
• MAXIMUM CHIMNEY LENGTH BETWEEN
AN OFFSET AND RETURN
•
MAXIMUM DISTANCE BETWEEN CHIM-
NEY STABILIZERS
•
DOUBLE OFFSET/RETURN MINIMUM
HEIGHT
•
MAXIMUM UNSUPPORTED CHIMNEY
LENGTH BETWEEN THE OFFSET AND
RETURN
•
MAXIMUM UNSUPPORTED CHIMNEY
HEIGHT ABOVE THE FIREPLACE
•
MINIMUM OVERALL STRAIGHT HEIGHT
IF FIREPLACE IS FREESTANDING
•
MINIMUM STRAIGHT HEIGHT
* Transition section standard with unit and 1
foot section of chimney will meet the mini-
mum 10 ft. for free standing installs.
SLA10 (for Canada) and CAK8A required for
Canada installation
NOTE: Offset can come off transition cone in all
instances, freestanding or otherwise.
Outdoor Lifestyles by Hearth & Home Technologies Inc. • ODCASTLEWD-42-B • 4070-160 Rev A • 10/22
FT
M
16
4.88
90
27.43
20
6.1
35
10.67
24
7.32
6
1.83
35
10.67
10
3.05
14.5
4.42
9 ft
11