Wiring Requirements - Outdoor Lifestyles ODFORTG-36 Installation Manual

Fortress indoor/outdoor
Hide thumbs Also See for ODFORTG-36:
Table of Contents

Advertisement

B. Wiring Requirements
Intellifire™ Touch Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IFT controlled appliance junction box to a switched circuit.
Incorrect wiring will override IFT safety lockout.
• Refer to Figure 8.3 or 8.4, IFT Wiring Diagram.
• This appliance is equipped with an Intellifire™ Touch
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
IFT-RC400
REMOTE
CONTROL
Figure 8.3 IFT Wiring Diagram
32
Outdoor Lifestyles by Hearth & Home Technologies • Fortress - ODFORTG-36 Installation Manual • 4602-901 Rev B • 8/17
FLAME
IGNITER
SENSE
ADAPTER
S
I
RF MODULE
6 PIN
RED
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
MODULE
RESET
WIRE ASSEMBLY
SWITCH
TO JUNCTION
BOX 110-120
VAC
GRN/WHT/BLK
LED
CONTROL
BLK
BRN
RED/
RED/
BLK
BLK
ACCESSORY CABLE
BRN
BRN
BLK
RED
JUMPER WIRE
POWER VENT
(OPTIONAL)

Hide quick links: