9.2 Dispenser warnings

In case of a warning message the relevant output is switched. The signal can be used for
interconnection with an external machine control. Warning W__5 activates only the special OD
warn output.
Message
W__0
W__2
W__3
W__4
W__5
W__6
Release 4/06
Meaning
New start signal from
product sensor while
ALX720 is dispensing a
label
Multiple signals from the
same product
Several missing labels on
the web, which can not be
compensated
Error while writing in the
EEPROM
RS232 transfer error
Conveyor speed exceeded
the max. speed of the
dispenser
Material end by the OD
control recognised
Too many products between
sensor and dispensing edge
Page 75
How to solve
Slow down conveyor speed or
product sequence.
Adjust higher labelling speed
Increase the parameter value
of PRDL product length
EEPROM defect, Start
machine again, if problem
remains the same, exchange
EEPROM as soon as possible
Check interface parameter in
the configuration menu and in
the host
Slow down conveyor. If
average conveyor speed is OK
then check for oscillation in the
conveyor speed or vibration of
the pulse generator
Insert a new material roll
Move the sensor closer to the
dispensing edge