Serial Interface; Data Of The Serial Interface - Avery Dennison ALS 230 User Manual

Avery dennison label maker user manual
Hide thumbs Also See for ALS 230:
Table of Contents

Advertisement

Operators Manual
ALS 230

7. Serial interface

The machine has a serial interface according to the standard RS232C. Via this interface
parameters can be adjusted. All received commands are tested for syntax and legal value
range.
Invalid commands and parameters are ignored. An error message is not given in this case.
All commands received over the serial interface are tested for syntax and range; invalid
commands and out of range parameter values are ignored. A warning message is not given in
these cases. However in the case of framing, parity or overrun errors the warning "W__3" is
generated.
The commands are made up of sequences of ASCII characters. Each command starts with "#"
and "!" followed by a 4 character code. The reception of the "#" character indicates the start of
a new command to the machine.
The codes are similar to the parameter names shown in the display.

7.1 Data of the serial interface

The pin connection of the interface plug is shown in the table below.
Dispenser connector
25 pol D-
9 pol D-
Sub
Sub
Socket 2
3
Socket 3
2
Socket 5
8
Socket 4
7
Socket 7
5
Socket 20
4
Socket 24
All other pins are not connected.
Adjustable data values
Baudrate
Data bits
Stop bits
Parity
Handshake
Factory
interface deactivated, at reactivation the parameters will be set to 8 data bits, 2
stop bits and no parity bit.
Release 11/05
Signal description
Direction
Code
Output
TxD
Input
RxD
Input
CTS
Output
RTS
GND
Output
DTR
(if jumper
+ 10V
on)
150, 300, 600, 1200, 2400, 4800, 9600, 19200 Baud
7 or 8 bits
1 or 2 bits
No Parity, Parity bit always 0, odd or even parity
RTS/CTS
Page 51
Description
Transmit data
Receive data
Clear to send
Request to send
For external use
PC
25 pol 9 pol
3
2
2
3
4
7
5
8
7
5
6
6
8
Serial interface

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents