Basic Settings - Phoenix Contact FL SWITCH SMN 6TX/2POF-PN User Manual

Smart managed narrow switch
Table of Contents

Advertisement

3
Startup and functions
8089_en_03
3.1

Basic settings

The basic Ethernet functions do not have to be configured and are available when the
supply voltage is switched on.
The procedure for switching to the supported operating modes via Smart mode is de-
scribed in Section "Using Smart mode" on page 20.
3.1.1
Delivery state/default settings
By default upon delivery or after the system is reset to the default settings, the following
functions and properties are available:
The password is: "private"
All IP parameters are deleted. The switch has no valid IP parameters:
IP address:
Subnet mask:
Gateway:
PROFINET is activated as the addressing mechanism.
All available ports are activated with the following parameters:
- Autonegotiation
- Autocrossing
All counters of the SNMP agent are deleted.
The web server, SNMP agent, and RS-232 interface are active.
Port mirroring, Rapid Spanning Tree, broadcast limiter, and MRP are deactivated.
The alarm contact only opens in the event of non-redundant power supply.
The transmission of SNMP traps is deactivated and the switch has no valid trap desti-
nation IP address.
The aging time is set to 40 seconds.
The WBM refresh interval is set to 30 seconds.
The switch is in "PROFINET" mode.
The transmission of SNMP traps is deactivated and the switch has no valid trap desti-
nation IP address.
The aging time is set using the "dot1dTpAgingTime" MIB object (OID 1.3.6.1.2.1.17.4.2).
The available setting range is 10 to 825 seconds. For static configuration, an aging time
of 300 seconds is recommended.
0.0.0.0
0.0.0.0
0.0.0.0
Startup and functions