Configuring The Switch As A Profinet Device - Phoenix Contact FL SWITCH SMN 6TX/2POF-PN User Manual

Smart managed narrow switch
Table of Contents

Advertisement

8089_en_03
Figure 9-2
The switch in the bus configuration under PC Worx
If the switch is not listed in the device catalog, the device description provided by Phoenix
Contact must be imported. The latest device description can be downloaded at
load.phoenixcontact.com.
If the device description is available in the device catalog, the following options are available
for bus configuration:
Manual - The components are transferred to the bus configuration from the device cat-
alog using drag & drop.
Automatic - The devices are entered via the "Read PROFINET" function, which means
that they can be accessed in the network via DCP (Discovery and Configuration Proto-
col). For this, the devices must be supplied with power and the operating mode must be
set to "PROFINET".
9.2.2

Configuring the switch as a PROFINET device

Once all switches have been added to the bus configuration, the following settings must be
made for the individual switches via the "Detail View" tab (device details):
The PROFINET device name must be checked and modified if necessary.
Operation as a PROFINET device