Electrical and mechanical characteristics:
R70/XX
Available frequencies (ISM bands)
AC current power supply range
DC current power supply range
Ingress protection
Antenna
Working frequency channel selection
Weight
Dimensions
EEPROM
Signaling
Connections
Maximun current over resistive load
Operating temperature
Storage temperature
Storage temperature –long periods-
Maximun comsumption
TM70Bi V3.2 (11/02)
1121174 L0.pdf
IKUSI reserves the right to change this information without prior notice.
Specifications
915MHz
870MHz/433MHz
419MHz
48V/115/230v AC
50/60Hz (+15% / -20% Vin)
8-32v DC
IP65 / NEMA-4
External (standard)
Fix or automatic (listen before talking EEPROM)
Maximum = 7 Kg (53 relays)
Length = 350 mm / Width = 250 mm / Heigth= 150mm
Internal and extractable (EP70)
MultiLED: internal LEDs
External input/output terminal plugs for using with
cable glands and base panel connectors
6A
-20ºC / +70ºC (-4ºF / 158ºF)
-25ºC / +75ºC (-13ºF / 167ºF)
-25ºC / +55ºC (-13ºF / 131ºF)
40 VA
81