9 Supplement
9 Supplement

9.1 Technical data

General data
Parameter, pressure
Measuring principle
Communication interface
Materials and weights
Materials, wetted parts
Process fitting
-
Diaphragm
-
Diaphragm with front flush version
-
Seal, O-ring
-
Materials, non-wetted parts
Internal transmission liquid
-
Housing
-
Terminal housing
-
Ground terminal
-
Plug
-
Cable gland
-
Plug seal
-
Connection cable
-
Available cable length max.
Weight approx.
Version with plug connector, cable outlet
-
Version with terminal housing
-
Torque max.
Output variable
Output signal
Zero and span adjustable via potentiometer
Dead time
Step response time (10 ... 90 %)
Standard version
-
24
Gauge pressure, absolute pressure, vacuum
Piezoresistive/Thin film DMS
None
316Ti
316Ti
316Ti, Hastelloy C4
FPM, FKM, EPDM, NBR
Synthetic oil, Halocarbon oil
316Ti
316Ti
316Ti
PA
PA, 316Ti
Silicone
PUR
40 m
0.2 kg (0.441 lbs)
0.35 kg (0.772 lbs)
50 Nm (36.88 lbft)
4 ... 20 mA
±5 %
≤ 1 ms
≤ 1 ms
Synthetic oil: For measuring ranges up to 16 bar, FDA listed for the food
2)
processing industry. For measuring ranges up to 25 bar not available.
Halocarbon oil: With version oil and greasefree, not with vacuum measuring
3)
ranges, not with absolute measuring ranges < 1 bar
2)3)
.
abs