6-2. Configuration Option Menu

1
1
Remote 14 Receptacle
2
Left Display
3
Right Display
4
Adjustment Control
5
Remote PC Interface
6
Setup Button
Setup
.
A complete Parts List is available at www.MillerWelds.com
2
-UP
SET
The Configuration Option Menu provides a
means to customize some machine features
for desired operation.
To enter the Configuration Option Menu, hold
the Setup Button down during power up while
the unit is displaying 8888 on the Left and
Right Displays. SET−UP will be displayed
3
4
momentarily.
Configuration options are displayed in the Left
Display. Settings are displayed in the Right
Display. Settings can be changed by turning
the Adjust Control. If a setting does not
change when the Adjust Control is turned, the
option is not configurable. Pressing the Setup
Button moves to the next configuration option.
5
6
256 367-A
OM-257219 Page 25