10.8.4 Turn ON the Appliance
1.
With the system in the OFF position, press the remote control
ON/OFF key to turn ON the appliance.
A single 'beep' will emit from the IFC module to confirm
reception of the command.
The LCD screen will display all active icons, and the IFC module
will start the ignition sequence.
10.8.5 Turn OFF the appliance
1.
With the system in the OFF position, press the remote control
ON/OFF key to turn ON the appliance.
A single 'beep' will emit from the IFC module to confirm
reception of the command.
The LCD screen will only display the room temperature and its
icon, and the IFC module will turn off the main burner.
10.8.6 Remote Control Flame Adjustment
This control system has (6) flame levels. If the smart thermostat
operation is activated, then the manual adjustment of the flame
height will be disabled.
1.
Verify the system is in the ON position and the flame level is
set at maximum.
2.
Press the down arrow key once to reduce flame height by
one level until the flame is turned off.
3.
Press the up arrow key once to increase flame height by one
step. If the up arrow key is pressed while the system is on,
but the flame is off, the flame will ignite on HI.
4.
A single 'beep' will confirm reception of the command.
Flame Off
Flame Level 5
10.8.7 Remote Control Thermostat Operation

10.8.7.1 Room Thermostat

The remote control can operate as a room thermostat. The
thermostat can be set to a desired temperature to control a
room's comfort level. To activate this function,
1.
Press the thermostat key. The LCD screen will display a
temperature bulb graphic, the room temperature and set
temperature.
2.
To adjust the set temperature, press the up or down arrow
keys until the desired temperature is displayed on the LCD
screen.
SP-41-L MANUAL REV#2 OCT 2017
Flame Level 1
Flame Level Maximum
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
SET TEMPERATURE

10.8.7.2 Smart Thermostat

The smart thermostat function will adjust the flame height based
on the set temperature and the actual room temperature. The
smart thermostat function automatically adjusts the flame down
when the room temperature reaches the set point. To activate this
function,
1.
Press the thermostat key until the 'SMART' appears on LCD
screen on the right side of the temperature bulb graphic.
2.
To adjust the set temperature, press the up or down arrow
keys until the desired temperature is displayed on the LCD
screen.
10.8.7.3 Deactivate Remote Control

Thermostat Operation

The thermostat operation function can be deactivated. The remote
control will still operate the main burner on and off, and function
flame, fan, and light modulation. To deactivate this function,
1.
Verify all (3) AAA batteries are installed in the remote control.
2.
Remove (1) AAA battery.
3.
While reinserting the battery, push and hold the thermostat
key. The temperature bulb graphic will not be displayed on
the LCD screen.
4.
To reactivate remote thermostat operation, follow the same
key sequence procedure above. The temperature bulb
graphic will reappear on the LCD screen.
ROOM TEMPERATURE
OPERATING INSTRUCTIONS
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-41-l

Table of Contents