Valor 739-72ILN/P Installation And Owner's Manual

Legend g3 series dv gas insert (contemporary black front & logs

Advertisement

739-72ILN/P (Contemporary Black Front & Logs)
DANGER
!
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall be
installed for the protection of children and other at-risk
individuals.
!
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
— Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
▪ Do not try to light any appliance.
▪ Do not touch any electrical switch; do
not use any phone in your building.
▪ Leave the building immediately.
▪ Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
▪ If you cannot reach your gas supplier,
call the fi re department.
— Installation and service must be
performed by a qualifi ed installer, service
agency or the gas supplier.
4004616-07
©2017, Miles Industries Ltd.
Legend G3
DV Gas Insert
Installation & Owner's Manual
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
L e a v e t h i s m a n u a l
w i t h t h e a p p l i a n c e .
R e t a i n t h i s m a n u a l
f o r f u t u r e r e f e r e n c e .
Please read this manual BEFORE
installing and operating this appliance.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Ce guide est disponible en français sur demande.
I N S TA L L E R
C O N S U M E R

Advertisement

Table of Contents
loading

Summary of Contents for Valor 739-72ILN/P

  • Page 1 Legend G3 DV Gas Insert 739-72ILN/P (Contemporary Black Front & Logs) Installation & Owner’s Manual DANGER I N S TA L L E R HOT GLASS WILL CAUSE BURNS. L e a v e t h i s m a n u a l w i t h t h e a p p l i a n c e .
  • Page 2 fi tter in the State assumes no responsibility for any consequential of Massachusetts. damage(s). Designed and Manufactured by / for Miles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com © Copyright Miles Industries Ltd., 2017...
  • Page 3: Safety Precautions

    Safety Precautions READ and UNDERSTAND all instructions carefully Due to the high temperature, the appliance should be before starting the installation. FAILURE TO FOLLOW LOCATED out of traffi c areas and away from furniture these installation instructions may result in possible fi re and draperies.
  • Page 4: Safety And Your Fireplace

    Child Safety Precautions and Recommendations, A physical barrier is strongly • recommended if there are young Parts of your Valor Fireplace become • children, or at-risk individuals in the extremely hot while in operation. house. Install an approved after- The glass viewing window •...
  • Page 5: Owner's Information

    EXTREMELY HOT!!! gas heater is a technical appliance that must be installed by a qualifi ed dealer. Each Valor fi replace is fully tested during • READ the SAFETY information on pages the production process for your safety and comfort.
  • Page 6: Annual Inspection

    OWNER’S Owner’s Information INFORMATION Annual Inspection In order to maintain the safe operation of your fi replace, contact your dealer to have a qualifi ed technician go over the list below and make the necessary verifi cations at least once every year. Annual Inspection List for a Safe Operation—to be performed by a qualifi...
  • Page 7: Cleaning Your Fireplace

    OWNER’S Owner’s Information INFORMATION Cleaning Your Fireplace To remove the window for cleaning: 1. Unhook the front with barrier screen. WARNING WARNING 2. On the window, DO NOT TOUCH THE GLASS WHILE IT IS HOT! turn each bolt a Let the fi replace cool fi rst before cleaning it. quarter turn to disengage the Important - Glass cleaning - Mineral deposits...
  • Page 8: Checking Pilot And Burner Fl Ames

    Damage caused by incorrect window installa- fl ammable vapors and liquids. tion is not covered by the Valor warranty. Inspect the vent terminal outdoors regularly to make 6. If the Hot Glass Warning plate has been removed...
  • Page 9: Using Handset Wall Holder

    OWNER’S Owner’s Information INFORMATION How to Turn Your Fireplace OFF To replace the batteries in the remote control (including pilot) receiver: First, ensure your fi replace is cooled BEFORE 1. The receiver is located to the left of the valve behind going ahead.
  • Page 10: Remote Control Operation

    OWNER’S Remote Control Operation INFORMATION Your fi replace remote control helps you get the comfort, convenience and aesthetics you want from your gas fi replace. The remote controls your fi replace in diff erent ways. IMPORTANT: BEFORE YOU BEGIN, please note that on this system, the settings of time, temperature and automatic ON/OFF can only be programmed when the function display is fl...
  • Page 11 OWNER’S Remote Control Operation INFORMATION Programming time and temperature You can set your fi replace to come on before you wake up and turn off after you leave and then, turn on again just before you come home and turn off after going to bed. You can leave it like this for the heating season.
  • Page 12: Kits & Accessories

    See your dealer for your choice of Outer Surrounds for children. and Trims. *Information accurate at the time of printing and subject to Other Accessories change without notice. 755CFK—Fan Kit 759EBL—Enamel Liners 760CBL—Ceramic Black Fluted Liners 4001515—Valor Red brick set...
  • Page 13: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot, which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • Page 14: Specifi Cations

    QUALIFIED Specifi cations INSTALLER Approval & Codes *High Altitude Installations This appliance is certifi ed to ANSI Z21.88-2014 / CSA I nput ratings are shown in BTU per hour and are 2.33-2014 American National Standard / CSA Standard certifi ed without deration for elevations up to 4,500 feet for Vented Gas Fireplace Heaters for use in Canada (1,370 m) above sea level.
  • Page 15: Overview

    QUALIFIED Overview INSTALLER This appliance may ONLY be installed in an existing unaltered, functioning solid-fuel burning fi replace with a working fl ue and constructed of non-combustible material. DO NOT install into combustible construction. This appliance is NOT APPROVED for installation with a zero clearance kit. WARNING WARNING Chimney Terminal Cap...
  • Page 16: Dimensions

    QUALIFIED Dimensions INSTALLER 28-5/8” (727 mm) 19-1/2” (495 mm) 12 - 14” (305 - 357 mm) Varies with outer trim options Optional Outer Trim or Surround sold separately 9-3/8 - 11-3/8” (238 - 289 mm) Varies with outer trim options 20”...
  • Page 17: Clearances

    QUALIFIED Clearances INSTALLER WARNING WARNING Some materials or items, although safe, may discolor, shrink, warp, crack, peel, and so on because of the heat produced by the fi replace. Avoid placing candles, paintings, photos, and other items sensitive to heat around the fi replace. Combustible Mantel Clearances Mantel Pro- 1”...
  • Page 18: Venting

    QUALIFIED Venting INSTALLER Typical Vent Installation See the Approved Venting Components list on page 29 of this manual. Vent Location The vent terminal must be located through the roof. This direct Terminal Cap vent appliance is designed to operate when an undisturbed airfl...
  • Page 19: Existing Fireplace Preparation

    QUALIFIED Installation Planning INSTALLER Only qualifi ed licensed or trained personnel should install this appliance. Installer—READ THIS FIRST 12. Refi t window. 1. YOU NEED TO KNOW FROM THE HOMEOWNER what accessories (surround, 13. Put batteries in receiver and remote control etc.) will be installed with this fi...
  • Page 20: Installation

    QUALIFIED Existing Fireplace Preparation INSTALLER Gas Line Routing Combustible Mantels Plan the routing of the gas line before proceeding. Combustible mantel clearances must conform to those Utilize the existing hole for the gas line. If the factory- required for the original solid-fuel fi replace into which built fi...
  • Page 21: Remove Window

    QUALIFIED Installation INSTALLER Remove Window The window is held in place by four spring-loaded bolts, two at the top and two at the bottom. 1. To remove the window, turn each bolt a quarter turn to disengage the bolt pin. 2.
  • Page 22: Connect Venting

    QUALIFIED Installation INSTALLER Connect Venting IMPORTANT: This appliance’s venting system is room sealed and therefore, does not require room air to be used in the combustion process. 1. Rough-in two 3” diameter vent liners into the existing chimney system from the roof. Be careful not to tear or damage the liners in the process.
  • Page 23: Connect Gas Supply

    QUALIFIED Installation INSTALLER Connect Gas Supply Pressure Test Points The gas supply inlet connection is a 3/8” NPT female The minimum supply pressure is given in the section connector and is located on the left hand side of the Specifi cations of this manual—page 14. control valve.
  • Page 24: Install Ceramic Logs

    QUALIFIED Installation INSTALLER Install Ceramic Logs Place it on the right pin located on the rear log. Rest its other end in the crook of the front right log. Unpack the ceramic logs very carefully to avoid damaging the fragile material. Install the logs as shown below. Please note that the position of the logs is critical to ensure proper performance of the appliance.
  • Page 25: Refi T And Check Window

    Damage caused by incorrect window installa- tion is not covered by the Valor warranty. 2. While you hold it, push in and turn the two bottom 6. If the Hot Glass Warning plate has been removed spring-loaded bolts a quarter turn to engage their pin.
  • Page 26: Connect Remote Control Receiver

    QUALIFIED Installation INSTALLER Connect Remote Control Receiver CAUTION CAUTION DO NOT PUT BATTERIES IN THE REMOTE DO NOT USE a screwdriver or other metallic object to CONTROL RECEIVER until the wires are con- remove the batteries from the receiver or the handset! nected to the burner control unit as short- This could cause a short-circuit to the receiver.
  • Page 27: Check Operation

    QUALIFIED Installation INSTALLER Check Operation Depending of fuel bed used, altitude and other considerations, the fl ame picture may be improved by Turn the fi replace fl ame up and down using the adjusting the aeration. The need for adjustment should remote control to confi...
  • Page 28: Install Front And Barrier Screen

    2. Hook the lower panel to the bottom of the front under the barrier screen. The 772 Contemporary Front is designed to be used on the Valor Legend G3 heater 739-72 along with an outer surround trim (supplied separately). The Contemporary Front fi ts within the outer surround trim and clips onto the standard mounting brackets supplied with the heater.
  • Page 29: Approved Venting Components

    QUALIFIED Approved Venting Components INSTALLER Approved Direct Vent Suppliers for Valor Models 700, 739 , 780, 785 and RF24DV Venting Parts Code / availability by Manufacturer Venting Parts Description 4DVC 940264 HSDV4658- Standard Co-axial 46DVA-VC 4DT-VC TM-4VT — 4DH-1313 —...
  • Page 30: Warranty

    The warranty registration card must be completed by the initial owner and returned to the Company within 90 days of purchase. Alternatively, the warranty registration form may be fi lled out online at www.valorfi replaces.com. b) Installation and maintenance must be performed by an authorized and trained dealer in accordance with the Company’s installation instructions.
  • Page 31: Spare Parts

    OWNER’S Spare Parts INFORMATION Part Part Code Description Code Description Number Number Exhaust Slide Assembly 4001133 Module Gasket—Left 4000181 Exhaust Slide Gasket 4001662 Olive Nut for Pilot Pipe 220K913 Fan Closure Plate 4001136 Pipe—Valve to Pilot 4001838 Port Cover 4001820 Thermal Switch Retainer 4001519 Log Support...
  • Page 32 OWNER’S Spare Parts INFORMATION Natural gas Propane gas Natural Propane gas 40a, 40b...
  • Page 33: Miles Industries Ltd

    Thank You ... For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only.
  • Page 34: Miles Industries Ltd

    Tape Shut Fold here Postage needed Miles Industries Ltd. 190 - 2255 Dollarton Highway North Vancouver, BC V7H 3B1 Canada Online Warranty registration at www.valorfi replaces.com Thank you for choosing a Valor Product...

Table of Contents