Probes; Electrode Area; Constants For Common Probe Materials - Honeywell XYR 6000 User Manual

Smartcet corrosion transmitter
Hide thumbs Also See for XYR 6000:
Table of Contents

Advertisement

2. Specifications

2.5. Probes

Authentication Device
Install the Authentication Device application on any PDA having
Windows Mobile version 4.2+
infrared port.
2.5
Probes

Electrode area

Three finger electrodes = 4.75 cm
Nine interleaved electrodes = 0.32 cm
Three flush disks = 0.40 cm

Constants for common probe materials

UNS
Number
Material
A91100
Aluminum 1100
A92024
Aluminum 2024
A95083
5083 Al
C11000
CDA 110ETP 99.9 Cu
C12200
DHP Cu
C27000
Yellow Brass
C44300
CDA443 (ARS AD. Brass)
C68700
CDA687 (Al Brass)
C70600
90-10 Cu-Ni [CDA 706 (Cu/Ni 90/10)]
C71500
CDA 715 (Cu/Ni 70/30)
G10100
1010 Carbon Steel
G10180
1018 Carbon Steel
G10200
1020 Carbon Steel
G10800
1080 Carbon Steel
G41400
4140
K01200
A179
K01201
A192
K02598
ASTM A36
K02700
A516-70 (A516 Gr70)
10
OneWireless XYR 6000 SmartCET Corrosion Transmitter User's Manual
2
2
2
Atomic Mass
(grams)
27.20
28.97
27.38
63.54
63.53
64.32
64.22
63.23
62.95
61.99
55.77
55.75
55.74
55.46
55.62
55.77
55.70
55.71
55.62
Number of electrons
Density
lost on oxidation
3
(grams/cm
)
(typical)
2.71
3
2.77
3
2.66
3
8.89
2
8.89
2
8.47
2
8.52
2
8.33
2
8.94
2
8.94
2
7.87
2
7.86
2
7.86
2
7.84
2
7.85
2
7.87
2
7.86
2
7.86
2
7.86
2
Revision 3
6/24/08

Advertisement

Table of Contents
loading

Table of Contents