Download Print this page

Honeywell XYR 6000 Quick Start Manual

Wireless transmitters. 24v external power module replacement
Hide thumbs Also See for XYR 6000:

Advertisement

Quick Links

Order Part No.
Qty.
50031428-501
1
Document Number
When to replace
When the transmitter displays LOW PWR and external power is present and sufficient. When the external power
is removed to allow replacement of the module, all transmitter data is retained in the transmitter's nonvolatile
memory.
Tools required
WARNINGS
ATTENTION
24V power module must be replaced only by a trained service technician.
WARNINGS
Risk of death or serious injury by explosion. Do not open transmitter
enclosure when an explosive atmosphere is present.
SHOCK HAZARD
Depending on your installation, transmitter input wiring sources may contain high
voltage. Disconnect all power from transmitter input sources before accessing the
24V power module. Failure to do so could result in death or serious injury if the
input terminals or wires are accidentally touched.
Sept 2009
XYR 6000 Wireless Transmitters
24V External Power Module replacement
Description
24 Vdc Power Supply Module
Form: 34-XY-33-10
Effective Date: September 2009
#1 Phillips Screwdriver or 1/8" Slotted Screwdriver
Torque Screwdriver
1.5 mm hex key
XYR 6000 24V External Module Replacement
1

Advertisement

loading

Summary of Contents for Honeywell XYR 6000

  • Page 1 Disconnect all power from transmitter input sources before accessing the 24V power module. Failure to do so could result in death or serious injury if the input terminals or wires are accidentally touched. Sept 2009 XYR 6000 24V External Module Replacement...
  • Page 2 Figure 1. 24V Power Supply Module Assembly 24V Wiring Connector M3 Locking Screw Power Connector Power Module Mounting Screws XYR 6000 24V External Module Replacement Sept 2009...
  • Page 3 0,4 – 0,6 N-M (3.5 – 5.3 Lb-in). Re-connect power and 24V connectors Honeywell recommends lubricating the end cap O-ring with a Silicone Grease such as Dow Corning #55 or equivalent before replacing the end cap. Screw the end cap back on and tighten the M3 locking screw.