Table of Contents

Advertisement

en
CHAPTER 7

7.3.2 Wiring

Figure 7.6 RJ11 Base station connector
Table 7.1 Pin configuration of the BS 0-7 and BS 8-15 connector
Installation Instructions
22
Connecting the base station
After mounting the base station on the wall, each base station must be connected to a
DCU through the unshielded twisted pair cable.
Proceed as follows (see fig. 7.6):
1. Connect a RJ11 plug to the cable at the base station end. Use the two inner
connectors [a] and [b] of the plug.
2. Insert the plug into the line connector of the base station.
n o t u
s e d
n o t c
o n n e
c t e d
n o t u
s e d
n o t c
a
o n n e
b
Connection base station-DCU
The connection of the base stations to the BS 0-7 or BS 8-15 connector of the DCU
(see figure 7.7) can be done in two different ways. One way is to solder the 25 pole male
sub D connector to the base station cables (see 1.), the other way is buying a BS-DCU
connection cable LBB 6721/02 (see 2.).
1. Soldering the wires to a 25-pole male sub D connector according the pin
configuration in Table 7.1 and plug the connector on the BS connector of the DCU
(see figure 7.7).
c t e d
Pin
Signal
1
a
14
b
2
a
15
b
3
a
16
b
4
a
17
b
DECT6000
BS
Pin
Signal
5
a
0/8
18
b
6
a
1/9
19
b
7
a
2/10
20
b
8
a
3/11
21
b
9...13
Not connected
22...25
Not connected
BS
4/12
5/13
6/14
7/15

Advertisement

Table of Contents
loading

Table of Contents