Wiring Requirements - Heatilator HEIR36H-IFT Installation Manual

Hide thumbs Also See for HEIR36H-IFT:
Table of Contents

Advertisement

NOTICE: DO NOT wire
110-120 VAC to wall switch.
Romex
Connector
14/2WG
GRN wire
inside box
Copper ground
attached to GRN
screw with GRN wire
Figure 8.2 Junction Box Detail
Accessories Requirements
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
• Hearth & Home Technologies recommends that Intel-
liFire
Touch wireless controls be used for their fea-
TM
tures and functionality with the IntelliFire
tion system.
Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors could
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17
B. Wiring Requirements
Intellifire
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.3, IntelliFire™ Touch Wiring Diagram.
• This appliance is equipped with an IntelliFire™ Touch
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
Touch igni-
TM
Touch Ignition System Wiring
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents