This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See appliance installation manual for additional
Commonwealth of Massachusetts requirements.
Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner's Manual • 2458-981 Rev. C • 2/17
Owner's Manual
Care and Operation
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator HEIR36T-IFT

  • Page 1 In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fi tter. See appliance installation manual for additional Commonwealth of Massachusetts requirements. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 2: Welcome

    00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 3: Table Of Contents

    D. Contact Information ......36  = Contains updated information. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 4: Limited Lifetime Warranty

    Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645H 10/15 Page 1 of 2 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 5 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645H 10/15 Page 2 of 2 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 6: Product Specifi C Information

    B. Glass Specifi cations This appliance is equipped with 5 mm ceramic glass. Replace glass only with glass with identical specifi cations. Please contact your dealer for replacement glass. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 7: Important Safety And Operating Information

    • Keep remote controls out of reach of children. • Never leave children alone near a hot fi replace, whether operating or cooling down. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 8: General Operating Parts

    GLASS CLIP TOOL GLASS CLIP TOOL RATING PLATE RATING PLATE Figure 3.3 Rating Plate/Glass Clip Tool Location Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 9 Sugges ons on how to further reduce TV temperatures: Increase “A” dimension. Increase “C” dimension, however, increasing “B” dimension beyond maximum recommended typically results in higher temperatures. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 10: Before Lighting Appliance

    • Ensure that the glass is sealed and in the proper position and that the integral barrier is in place. WARNING! Risk of Fire or Asphyxiation! DO NOT op- erate fi replace with fi xed glass assembly removed. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 11: Lighting Instructions (Ipi)

    Keep burner and control compartment clean. See installation and operating instruc- Propane Installation code, CSA B149.1. tions accompanying appliance. For additional information on operating your 593-913i Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 12: Appliance Break-In

    If this occurs, restart the appliance. NOTICE! Open windows for air circulation during fi re- place break-in. • Some people may be sensitive to smoke and odors. • Smoke detectors may activate. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 13: Operation During A Power Outage - Intellifi Re™ Touch

    NOTICE: Some functionality will be lost when using battery backup including fan, lights, or any other auxiliary functions that require household 110-120 VAC power. 3.5 Battery Pack Location Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 14: Detailed Component Operating Instructions - Intellifi Re™ Touch

    - Be aware the appliance may be HOT, use switch is NOT available if a Power Vent is used. care in accessing the IFT-ECM. - Set the IFT-ECM 3-position selector switch to OFF position. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 15 HI, ® MED, LO or OFF. The Fan Speed dynamic icon is used to change the setting. Refer to the RC400 quick reference guide in section 6.C. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 16: Maintenance And Service

    CAUTION! Risk of Burns! The fi replace should be turned off and cooled before servicing. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 17: Maintenance Tasks - Qualifi Ed Service Technician

    • Inspect fi xed glass assembly for scratches and nicks that can lead to breakage when exposed to heat. • Confi rm there is no damage to glass or glass frame. Replace as necessary. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 18 • Verify batteries have been removed from battery back- up IPI systems to prevent premature battery failure or leaking. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 19: Frequently Asked Questions And Troubleshooting

    No action necessary. This appliance ships with a non-combustible material attached. Speci- Wall above appliance feels hot to fi cations of the attached non-combustible material are listed in the Installer’s Manual for this the touch. appliance. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 20: Frequently Asked Questions - Intellifire™ Touch Controls (Ift-Rc400)

    “Remote Control Communication Power outage. Install new batteries in battery backup. Error.” Contact your dealer for additional information regarding operation and troubleshooting. Visit www.heatilator.com to locate a dealer. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 21: Troubleshooting

    If open or shorted, replace valve. Check valve harness wire continuity, if open replace 6-pin harness. Pilot won’t light, there is no noise Spark coil failure. Replace ECM. or spark, 2 Red/2 Green Lockout. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 22 Check re- Damaged pilot assembly. IFT- sistance between tip of sense rod and ECM connector, should be less than 1 ohm. Replace pilot assembly if damage is detected. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 23: Reference Materials

    HEIR36-IFT and HEIR42-IFT appliances. It must be in- stalled by a qualifi ed service technician during the appli- ance installation process. Follow the instruction supplied with the kit for operation. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 24: Service Parts

    Glass Assembly GLA-2283 Finishing Spacer 2281-113 Pilot Cover 2281-187 Burner Assembly 2283-007 Ori ce Bracket Flex 2012-008 Access Plate 2281-117 Additional service parts on following page. 2/17 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 25 Refractory, Left Base SRV2283-721 20.5 Refractory, Front Base SRV2283-720 20.6 Refractory, Right Base SRV2283-722 20.7 Refractory, Right SRV2283-724 20.8 Refractory, Back SRV2283-725 Additional service parts on following page. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 26 Glass Assembly GLA-2284 Finishing Spacer 2281-113 Pilot Cover 2281-187 Burner Assembly 2284-007 Ori ce Bracket Flex 2012-008 Access Plate 2281-117 Additional service parts on following page. 2/17 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 27 Refractory, Left Base SRV2284-721 20.5 Refractory, Front Base SRV2284-720 20.6 Refractory, Right Base SRV2284-722 20.7 Refractory, Right SRV2284-724 20.8 Refractory, Back SRV2284-725 Additional service parts on following page. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 28 2281-113 Pilot Cover 2281-187 Burner Assembly, NG 2285-007 Burner Assembly, LP 2285-008 Ori ce Bracket Flex 2282-161 Access Plate 2281-117 Additional service parts on following page. 2/17 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 29 Refractory, Front Base SRV2285-720 21.5 Refractory, Right Base SRV2285-722 21.6 Refractory, Back Bottom SRV2285-725 21.7 Refractory, Right SRV2285-724 21.8 Refractory, Back SRV2285-727 Additional service parts on following page. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 30 Ori ce NG (#24C) 582-824 HEIR50-IFT Ori ce LP (#43C) 582-843 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 250v, 1A fuse, 3/4” long Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 31 Conversion Kit NG NGK-HEIR50 HEIR50-IFT Conversion Kit LP LPK-HEIR50 Pilot Ori ce NG 593-528 Pilot Ori ce LP 593-527 Regulator NG w/stepper motor NGK-DXV-50 Regulator LP w/stepper motor LPK-DXV-50 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 32 Depot ITEM DESCRIPTION COMMENTS PART NUMBER HEIR36-IFT 2280-366 Trim Strip, Sides (Qty 2 req) HEIR42-IFT 2281-366 HEIR50-IFT 2282-366 HEIR36-IFT 2280-367 Trim Strip, Top HEIR42-IFT 2281-367 HEIR50-IFT 2282-367 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 33: Ift-Rc400 Intellifire™ Touch Remote Control User Guide

    OFF. During thermostat use, you will not be able to set your between the RT and ST. Flame Height ambiance and control the heat output. start. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 34 Note: Battery backup is not available if a Power Vent is installed. Cold-climate function and battery backup are disabled if a Power Vent is used. * = Optional Feature Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 35 For the location of your nearest 2) This device may accept any interference, including interfer- Hearth & Home Technologies dealer, ence that may cause undesired operation of the device. please visit www.hearthnhome.com. Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...
  • Page 36: Contact Information

    5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945C Printed in U.S.A. - Copyright 2017 Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17...

Table of Contents