Finishing; Facing Material - Heatilator HEIR36H-IFT Installation Manual

Hide thumbs Also See for HEIR36H-IFT:
Table of Contents

Advertisement

10

Finishing

A. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or finishing materials must not interfere
with air flow through louvers, operation of louvers or
decorative fronts, or access for service.
• Facing and/or finishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping materials could ignite and will
interfere with proper operation of decorative fronts and
louvers.
COMBUSTIBLE MATERIAL
0 IN.
0 in.
NON-COMBUSTIBLE
A
MODEL
in.
HEIR36
61
HEIR42
67
HEIR50
75
Figure 10.1 Non-combustible Facing Diagram
NOTICE: Surface temperatures around the appliance will
become warm while the appliance is in operation. Ensure
finishing materials used for all surfaces (floor, walls,
mantels, etc.) will withstand temperatures up to 190°F.
Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17
0 IN.
A
B
BOARD
B
mm
in.
mm
1549
57-5/8
1464
1702
62-5/8
1591
1905
66-5/8
1692
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents