When the DIALPAD feature is programmed to be
ON, the speakerphone will activate automatically
when pressing any number on the dial pad keys .
The LED above the SPEAKER key will illuminate to
indicate that the speakerphone is in-use .
To hang-up, press the SPEAKER key again .
To use the handset, pick up the handset from
the cradle and the handset will be active . The
speakerphone will disconnect . To re-activate the
SPEAKER key, press the SPEAKER key and place
the handset back into the cradle .
Programming (SP-300, SP-400)
PROGRAMMING FLASH TIMING INTO
MEMORY
Flash Timing can be programmed into the
SpectrumPlus speed dial memory . This function
allows for a timed line break in the sequence of
the dialing patterns when using the speed dial
keys . This function may be required for accessing
line features provided by your telephone system or
local telephone company . The flash timing options
are 100 through 1000 milliseconds, programmable
in 100 mS increments .
TO FIND THE CORRECT FLASH TIMING
The factory default Flash Timing is programmed
at 600 mS and is the most commonly used timing
option . However, the timing can be reprogrammed
between 100 mS to 1000 mS, when needed .
1 . Check with your local service provider or
PBX provider to select the appropriate
timing .
2 . If different timing is required, follow the
Flash Time Programming instructions on
the next page .
10
USING A FLASH WHEN DIALING
To use a Flash when dialing, simply press the
FLASH key at the appropriate point in the number
sequence being dialed from the key pad .
Note: Each Flash counts as 1 digit when stored
into a speed dial memory location .
PROGRAMMING FLASH TIMING
Flash timing can be programmed for different
timing options listed below .
1 . Position the handset in the off hook position
(lift the handset) .
2 . Press the STORE key once .
3 . Press "*" key for 3 seconds until an alert
sound is heard .
4 . Press the following keys on the keypad in
the order shown:
For 100 mS press "1", then "#" .
For 200 mS press "2", then "#" .
For 300 mS press "3", then "#" .
For 400 mS press "4", then "#" .
For 500 mS press "5", then "#" .
For 600 mS press "6", then "#" .
For 700 mS press "7", then "#" .
For 800 mS press "8", then "#" .
For 900 mS press "9", then "#" .
For 1000 mS press "0", then "#" .
5 . Place the handset cradle to the on hook
position .
Programming Example for 100 mS
Go off hook with handset, press STORE once, then
"*" for 3 seconds to enter set up mode, then "1",
then "#" . Place the handset into cradle to the on
hook position .
Note: The Flash timing factory default is 600 mS .
PROGRAMMING PAUSE TIMING
A Pause time between 1 .0 seconds to 5 .0 seconds
can be programmed into memory . This function
www.telematrix.net