6. Attach 24 V Class 2 power supply to terminals on
the power switch: +24 VDC to terminal 2 (+) and 24
VDC return to terminal 5 (-). See F
protective earthing (PE) conductor to terminal
marked
. See F
IG
must be capable of supplying at least 1.0 Amp and
have supply current protection rated at no more
than 2.5 Amps.
7. Install cover plate (160), screws (156), and washers
(164).
8. Install shrouding covers. See DataTrak Kit parts
illustration on page 62.
Remove 100-240 VAC Power Supply
1. Turn power supply OFF and Disconnect power.
2. Remove shrouding covers (506, 507). See Data-
Trak Kit parts illustration on page 62.
3. Remove two screws (156), two washers (164), and
press cover plate (160) up from the bottom. Then
slide to front of ram to remove.
154a
157a
164
156
F
. 39
IG
4. Disconnect power supply output cable.
5. Remove quick disconnects from rocker switch.
6. Remove ground screw (166).
7. Remove screws (156) and 100-240 VAC power
supply (154a) from power supply mounting bracket
(151).
313527ZAD
. 37. Attach
IG
. 38. The 24 VDC power supply
163
151
166
161
160
TI10851A
8. Inspect all parts for wear or damage. Replace as
needed.
Replace 100-240 VAC Fuses
1. Turn power supply OFF and Disconnect power.
2. Use screwdriver to remove two fuses (165) from
module and install new fuses.
F
. 40
IG
Install 100-240 VAC Power Supply
1. Turn power supply OFF and Disconnect power.
2. Mount power entry module (157a) and 100-240
VAC power supply (154a) on mounting bracket
(151).
3. Install power supply output cable to CAN cable
(509). See F
. 39.
IG
4. Connect power supply input quick disconnects to
power switch terminals (157a).
a. Connect green wire to Ground
b. Connect brown wire to Line (L).
c. Connect blue wire to Neutral (N).
5. Install grounding screw (166) through eyelet termi-
nal of power supply ground (green) pigtail wire and
fasten to power supply enclosure (151).
6. Install cover plate (160), screws (156), and washers
(164).
7. Install shrouding covers. See DataTrak Kit parts
illustration on page 62.
Repair
165
TI10852A
.
37