3.2.3.7 Fusing Unit Disassembly

This section describes how to remove the paper exit sensor, heater lamp, lower fusing roller, and
upper fusing roller.
Heater Lamp
Do not touch the glass surface of the lamp with your bare hands.
1.
Remove the fusing guide plate. (Refer to Section 3.2.3.6.)
2.
Pull the heater lamp out of the lamp holder from the front side.
When reinstalling the lamp, position its voltage indication to the left side (non-gear end.).
Rev. B
CAUTION
Figure 3-21. Removing the Heater Lamp