Troubleshooting
Cause
The interlock switch lever is
bad.
The interlock switch may be
dead.
The PWB-E board may be
dead.
The paper take-up sensor flag
position may be incorrect.
The paper exit sensor flag
position may be incorrect.
The paper take-up sensor
connector
may
disconnected.
The
paper
exit
connector
may
disconnected.
The paper exit sensor may be
dead.
The paper take-up sensor may
be dead.
5-8
Step
Does the switch turn on when
1
the case is closed?
Does
the
2
(Check with a multimeter.)
With power on, is there an
output of +24 VDC between
3
pin 1 (+) and pin 2 (–) for
CN207
board?
Is the paper take-up sensor
4
flag position OK?
Is the paper exit sensor flag
5
position OK?
Is the paper take-up sensor
be
6
connector disconnected?
sensor
Is
the
be
7
connector disconnected?
—
8
—
9
Checkpoint
Finding
switch
toggle?
on
C169
MAIN-B
paper
exit
sensor
EPL-5500 Service Manual
Solution
Replace the interlock
No
lever.
Replace the interlock
No
switch.
Replace the PWB-E
board.
No
Reposition the paper
No
take-up sensor flag.
Reposition the paper
No
exit sensor flag.
Connect it.
Yes
Connect it.
Yes
Replace it.
—
Replace it.
—
Rev. B